With display |
No |
Voltage type for actuating |
AC/DC |
Rated operating voltage Ue |
200 V |
Rated control supply voltage at AC 50 Hz |
100 V |
Rated control supply voltage at AC 60 Hz |
100 V |
Overload current |
28.3 A |
Controller type |
SMC-3 |
DV/DT protection |
1000V/µs for power circuit |
Repetitive peak voltage |
1400V per UL/CSA/NEMA for power circuit |
Operating frequency |
50/60 Hz per UL/CSA/NEMA for power circuit |
Line connected motor power, max |
45 kW @ 380/400/415V AC, 50 Hz, 3-phase |
Delta connected motor power, max |
25...100 Hp @ 460V AC, 60 Hz, 3-phase |
Overvoltage category |
III per IEC for side mount auxiliary contacts |
Rated impulse voltage |
6 kV for power circuit |
Dielectric withstand |
2500V AC per IEC for power circuit |
Line connected motor current |
28.3...85 A @ 380/400/415/460V AC, 3-phase |
Delta connected motor current |
50...147 A @ 380/400/415/460V AC, 3-phase |
Insulation voltage |
Rated 600V AC per UL/CSA/NEMA for power circuit |
Rated operational voltage |
250V AC/30V DC per UL/CSA/NEMA for Side mount auxiliary contacts |
Rated control power during start with fan |
200 mA @ 120V AC/100 mA @ 240V AC, 700 mA @ 24V AC/DC |
Input OFF-state current |
<10 mA, <12 mA @ input OFF-state voltage (IN1, IN2) for control circuit |
Short-circuit protection device list |
Non-time delay Thermal magnetic circuit breaker High capacity time delay class CC/J/L |
Number of contacts |
TB-97, -98 (OVLD/Fault): 1 for auxiliary contacts |
High capacity available fault current, max |
70 kA @ 600V, maximum current 300 A time delay Class J or Class L fuse for inside delta connected motors |
Type of current |
TB-97, -98 (OVLD/Fault): AC/DC for auxiliary contacts |
Conventional thermal current (Ith) |
TB-97, -98 (OVLD/Fault): 1 A for auxiliary contacts |
Type of control circuit |
TB-97, -98 (OVLD/Fault): Electromagnetic relay for auxiliary contacts |
Type of contacts |
TB-97, -98 (OVLD/Fault): Normally Open (N.O.) for auxiliary contacts |
Utilization category |
TB-23, -24 (normal/up-to-speed), TB-33, -34 (normal/up-to-speed): C300/R150 per UL/CSA/NEMA for Side mount auxiliary contacts |
Rated operational current, max |
TB-97, -98 (OVLD/Fault): 0.6 A @ 120V AC and 0.3 A @ 240V AC for auxiliary contacts |
Standard controller feature |
Soft stop |
Standard available fault current, max |
10 kA @ maximum standard fuse 400 A for delta device operational current rating |
Integrated motor overload protection |
Yes |
Short circuit protection device performance (SCPD) type |
Type 1 |
Selectable overload trip class |
Trip Class 10, 15, or 20 |
Selectable start times |
2, 5, 10, 15, 20, 25, or 30 s |
Input OFF-state voltage (IN1, IN2), max |
40V AC, 17V DC/12V AC for control circuit |
Selectable current limit |
150%, 250%, 350%, and 450% of full load current |
Input ON-state voltage, during start (IN1, IN2) |
85V AC, 19.2V DC/19.2V AC minimum for control circuit |
Input ON-state current (IN1, IN2) |
9.8 mA @ 120V AC/19.6 mA @ 240V AC for control circuit, 7.3 mA @ 24V AC/DC for control circuit |
Degree of protection (IP) |
IP2X |
Weight |
2.25 kg |
Shock |
Operational: 15 G |
Width |
72 mm (2.83 inch) |
Depth |
130 mm (5.12 inch) |
Height |
206 mm (8.11 inch) |
Cable size |
2.5...95 mm2 (14...3/0 AWG) for line power terminals |
Vibration |
Operational: 1.0 G peak, 0.15 mm (0.006 inch) displacement |
Make |
TB-97, -98 (OVLD/Fault): 432VA for auxiliary contacts |
Break |
TB-97, -98 (OVLD/Fault): 72VA for auxiliary contacts |
Tightening torque |
11.3...12.4 Nm (100...110 lb.inch) for load power terminals |
Internal bypass |
Yes |
Function |
Single direction |
Selectable kick start - 450% FLA |
0, 0.5, 1.0, or 1.5 s |
Selectable initial torque |
15%, 25%, 35%, and 65% of locked rotor torque |
Selectable soft stop |
Off, 100%, 200%, or 300% of the start time setting when wired |
Steady state heat dissipation |
82 W |
Storage and transportation temperature |
-25 °C |
Rated surrounding temperature range without derating |
-5 °C |
Humidity |
5...95% noncondensing |
Operating temperature |
Open: -5 to 50 °C (23 to 122 °F) |
EMC emission levels |
Radiated emission: Class A per IEC |
EMC immunity levels |
Surge transient: per EN/IEC 60947-4-2 per IEC |
Altitude |
2000 m |
Pollution degree |
2 |
Mounting hole size |
5.3 mm |
Number of poles |
Equipment is designed for 3-phase only for power circuit |
Enclosure |
Open type |
-
China CCC
-
Eurasion Economic Community
-
Australian RCM
This product was certified with the above certifications as of 2024-04-01. Products sold before or after this date might carry different certifications. Please review the product label to check for the certifications your specific product carries.