MV and HV insulation under full control
The S-110DC device is a universal high voltage tester. It is extremely durable, but also lightweight, compact and easy to carry due to its transport case on wheels.
Capacitive objects, such as shielded power cables, will be correctly and automatically discharged by the integrated discharge module if an error occurs or the test time expires. A key switch, a switch-on lock and a protective earthing circuit ensure maximum safety.
Sonel offers online training course on the use of this product (instructional video and consultation with a specialist).
Features
Technical Specification
S-25 DC | S-50 DC | S-80 DC | S-110 DC | S-120 DC | |
---|---|---|---|---|---|
Power supply | • internal rechargeable battery • mains, switchable 115 / 230 V, 50-60 Hz • external DC voltage source | mains 230 V / 50 Hz (optional: 115 V / 60 Hz | mains 230 V / 50 Hz (optional: 115 V / 60 Hz | mains 230 V / 50 Hz (optional: 115 V / 60 Hz | mains 230 V / 50 Hz (optional: 115 V / 60 Hz |
Power consumption | max. 120 VA | max. 900 VA | max. 900 VA | max. 900 VA | max. 900 VA |
Output voltage | • 0…25 kV DC • infinitely adjustable • negative polarity • ripple < 0,25% | • 0…50 kV DC • infinitely adjustable • negative polarity | • 0…80 kV DC • infinitely adjustable • negative polarity | • 0…110 kV DC • infinitely adjustable • negative polarity | • 0…120 kV DC • infinitely adjustable • negative polarity |
Rated output current at max. output voltage | 1.5 mA electronically limited | 6 mA | 5 mA | 4 mA | 3,5 mA |
Battery operation at full load | 45 min | - | - | - | - |
Discharge - integrated automatic discharge device | 3000 J 9.6 µF at 25 kV | 7500 J 6 µF at 50 kV | 12 250 J 4 µF at 75 kV 3.5 µF at 80 kV | 15 000 J 3 µF at 100 kV 2.5 µF at 110 kV | 18 750 J 2.4 µF at 125 kV 2.6 µF at 120 kV |
Voltage measuring range | 0…30 kV | 0…50 kV | 0…80 kV | 0…110 kV | 0…130 kV |
Current measuring ranges | 0…200 µA / 0…2 mA manual or automatic switching between ranges | 0…100 μA / 1 mA / 10 mA manual switching between ranges | 0…100 μA / 1 mA / 10 mA manual switching between ranges | 0…100 μA / 1 mA / 10 mA manual switching between ranges | 0…100 μA / 1 mA / 10 mA manual switching between ranges |
Operating temperature | -25…+55°C -13…+131°F |
-25…+55°C -13…+131°F |
-25…+55°C -13…+131°F |
-25…+55°C -13…+131°F |
-25…+55°C -13…+131°F |
Storage temperature | -40…+70°C -40…+158°F |
-40…+70°C -40…+158°F |
-40…+70°C -40…+158°F |
-40…+70°C -40…+158°F |
-40…+70°C -40…+158°F |