HI935007 Foodcare K-Type Thermocouple Thermometer with Fixed Attached Probe

HI935007 Foodcare K-Type Thermocouple Thermometer with Fixed Attached Probe

分类: Thermocouples / Thermistors / Pt100 已售罄
可在官方网站购买
RM 567.00 欲了解更多详情,请游览我们的官方网站 hannamalaysia.com

详情

Designed with user functionality and performance in mind, the HI935007 is a waterproof K-Type thermocouple thermometer that measures temperature from -50.0 to 300°C (-58.0 to 572°F). The included batteries provide up to 3500 hours of continuous use. CAL Check™ and the Battery Error Prevention System (BEPS) ensure that the readings are accurate. The probe is permanently attached to the meter and is not replaceable


The HI935007 is a waterproof portable K-Type thermocouple thermometer made for the food professional that is required to monitor temperature as part of a hazardous analysis of critical control points (HACCP) plan including in food service, production, packaging, transportation, restaurants or catering. The HI935007, as a meter, can measure over a wide range of temperatures from -50.0 °C (-58.0 °F) up to 300 °C (572 °F) and offers a very high accuracy of ±0.4 °C (±0.7 °F). The accuracy of the meter is assured with advanced diagnostic features including CAL-Check that checks for abnormal drift of the internal electronics, battery error prevention system (BEPS) that will not allow a reading to be taken when there is not sufficient battery power and probe diagnostics that alert the user when the probe is not connected or has been damaged.

HI935007 Foodcare thermometer is supplied with a fixed attached penetration K-Type thermocouple probe that will reach 90% of the final reading within 15 seconds. The tip of FC766PW is just 3 mm (0.12'') in diameter allowing for easy penetrations into solids and semi-solids. The AISI 316 stainless steel body is 155 mm (6.1'') long and is safe for food contact in compliance with Regulation (EC) 1935/2004.

There are many considerations when designing a thermometer for the food professional. Below are features that we considered to be important and beneficial.

 HI935007 CAL Check

 

CAL Check

The calibration check (CAL Check) feature of the HI935007 is an internal diagnostic feature that checks for any drift in the electronics that occurs with all digital thermometers over time. When the meter is turned CAL Check looks to see if the internal calibration is within +/- 0.3 °C. If the drift is greater and error (err) message will be displayed. With CAL Check you can be confident that the meter is working properly.

Low Battery Indicator

The included AAA batteries provide 3500 hours of continuous use. When the battery level is below 10%, a warning symbol will blink to indicate low battery condition. When low battery power may affect your results, the meter will shut down to avoid erroneous readings caused by low battery level.

Damaged Probe Messages

If the probe is damaged the message will be displayed along with four blinking dashed lines. For an accurate temperature measurement it is important to know that not only is the meter working properly but that the probe is okay.

Penetration K-Type Thermocouple Probe

 

Fast Response Probe

The attached penetration K-Type thermocouple probe that will reach 90% of the final reading within 15 seconds.

 

Small Penetration Tip

The tip of the probe is just 3 mm (0.12'') in diameter allowing for easy penetrations into solids and semi-solids.

 

AISI316 Stainless Steel Body

The AISI 316 stainless steel body is 155 mm (6.1'') long and is safe for food contact in compliance with Regulation (EC) 1935/2004.

Additional Features/Benefits:

Supplied with Instrument Quality Certificate

  • HI935007 with the K-Type penetration probe are calibrated according to an ISO9001 calibration system using standards and reference instruments in which the accuracy is traceable the National Institute of Standards (NIST) in the USA, or to internationally acceptable physical standards. For traceability, the HI935007 meter is supplied with an instrument quality certificate including measured values along with reference values.

Large LCD

  • An enhanced LCD displays the measurement reading in oC or oF, stability indicator, error messages, and low battery indicator.

Stability Indicator

  • An hourglass indicator is displayed on the LCD until a stable reading is obtained. Once a reading stabilizes, the indicator disappears and a reading can be taken.

 

Automatic Shut-off

  • The meter can be set to automatically turn off after 8 minutes or 60 minutes to conserve battery life in the event that the meter is left on. The auto-off feature can also be disabled.

Ergonomic, rugged, waterproof (IP65) design

  • For additional protection the HI710027 shockproof rubber boot is available as an accessory.

SKU HI935007
Product Name Foodcare K-Type Thermocouple Thermometer with Fixed Attached Probe - HI935007
Quote Required Yes
K-Type Thermocouple Temperature Range -50.0 to 199.9 oC; 200 to 300 oC
-58.0 to 399.9 oF; 400 to 573 oF
K-Type Thermocouple Temperature Resolution 0.1 oC (-50.0 to 199.9 oC); 1 oC (200 to 300 oC)
0.1 oF (-58.0 to 399.9 oF); 1 oF (400 to 573 oF)
K-Type Thermocouple Temperature Accuracy +/- 0.4 oC (-50.0 to 300 oC)
+/- 0.7oF (-58.0 to 573 oF)
Temperature Probe K-Type attached penetration probe (fixed)
Automatic Shut-Off user selectable
Battery Type/Life 1.5V AAA battery (3 pcs.) / approximately 3500 hours of continuous use
Environment operating conditions
Dimensions 140 x 57 x 28 mm (5.5 x 2.2 x 1.1”)
Weight 178 g (6.27 oz.)
Ordering Information HI935007 is supplied with K-Type thermocouple penetration probe, batteries, instruction manual, and instrument quality certificate.

更多 Hanna Instruments (M) Sdn Bhd 相关资料
Hanna Instruments (M) Sdn Bhd
Hanna Instruments (M) Sdn Bhd Measuring Instruments Selangor, Photometers Supply Penang, Sabah, Test Equipments Supplier Malaysia ~ Hanna Instruments (M) Sdn Bhd