Why We Use Air Filters of Compressor?
●The compressed air contains contaminations including moisture, pipe scale and rust.
●Without filters, instruments and tools will malfunction.
●Maintenance of the compressed air system costs will increase and end products will be spoiled.
How Filters Work? How To Select?
●Cspeice filters feature an inside and outside air flow, a long understood and proven method of combining filtration efficiency and energy efficiency.
●The inner element surface acts as a pre-filter to remove most water, dust and contaminants.
●The larger outside pores allows the air stream to pass smoothly to minimize the pressure drop.
Specification | Pre-filter | General Purpose | Oil Removal | Activated Carbon | |
Grade | XQ | XP | XS | XC | |
Particle Removal (Micron) | 3 | 1 | 0.01 | 0.01 | |
Max. oil carry over at 21°C (mg/m3) | 3 | 0.5 | 0.01 | 0.003 | |
Max. working temperature ( °C) | 80 | 80 | 80 | 50 | |
Initial pressure loss (mbar) | 40 | 80 | 100 | 80 | |
Pressure loss for element change (mbar) | 700 | 700 | 700 | 700 | |
Max working pressure (barg) | 16 | 16 | 16 | 16 |
Surface Protection ●All sizes of housings are unique surface treatment of corrosion resistant both inside and outside. |
|
|
High Efficiency & Life Span ●Unique element interface for high efficiency filter performance. ●Filter element performance quaranteed for 12 months. ●Cespeice filter elements have 8-10um pores on the inner surface, and widening to 40-80um pores on the outer surface for optimize filtration efficiency versus pressure drop. |
Certificate ●Air Quality performance tested in accordance with ISO9001. ISO9001 assumes customers of an efficient and reliable management system,designed to ensure consistent levels of customer service. |
Qulity class | Solid particles, max. amount of particles per m3 | Pressure dew point | Oil(incl. oil vapour) | Air qualities in accordance with ISO 9001 | ||
0.1-0.5 um | 0.5-1.0 um | 1.0-5 um | ℃ at 7 bar | mg/m3 | Depending on the filtration stage. The requirement of ISO 9001 are even exceeded. Therefore, you can firmly rely on CSPEICE filters | |
1 | ≦20,000 | ≦400 | ≦10 | ≦-70 | ≦0.01 | |
2 | ≦400,000 | ≦6,000 | ≦100 | ≦-40 | ≦0.1 | |
3 | _ | ≦90,000 | ≦1,000 | ≦-20 | ≦1.0 | |
4 | _ | _ | ≦10,000 | ≦+3 | ≦5 | |
5 | _ | _ | ≦100,000 | ≦+7 | >5 | |
6 | ≦5 mg/m3 | ≦+10 | _ |
Filter model | PIPE size (inches) | Flow rate(m3/min) | Element mode | Housing dimensions(mm) | |||
A | B | C | |||||
Ported range | NT2312 | 3/4' | 1.2 | M72 | 248 | 240 | 100 |
NT2320 | 3/4' | 2 | M120 | 248 | 240 | 100 | |
NT2334 | 1 | 3.4 | M204 | 313 | 240 | 100 | |
NT2346 | 1 1/2' | 4.6 | M276 | 398 | 390 | 130 | |
NT2371 | 1 1/2' | 7.1 | M426 | 398 | 390 | 130 | |
NT2418 | 2' | 11.8 | M708 | 488 | 480 | 172 | |
NT2489 | 2' | 18.9 | M1134 | 488 | 480 | 172 | |
NT2560 | 2 1/2' | 26 | M1560 | 845 | 837 | 200 | |
NT2670 | 3' | 37 | M2220 | 845 | 837 | 200 | |
Flanged range | NT2687F | DN80 | 37.8 | M1134*2 | 1150 | 490 | |
NT2876F | DN100 | 56.7 | M1134*3 | 1150 | 710 | ||
NT3065F | DN150 |
75.6 |
M1134*4 | 1150 | 990 | ||
NT3254F | DN150 | 94.5 | M1134*5 | 1150 | 1070 | ||
NT3340F | DN150 | 130 | M1560*5 | 1150 | 1070 |