Fluke 414D Laser Distance Meter
Distance Measurement |
Typical Measuring Tolerance[1] |
± 2.0 mm [3] |
Maximum Measuring Tolerance[2] |
± 3.0 mm [3] |
Range at Leica target plate GZM26 |
50 m / 165 ft |
Typical Range[1] |
40 m / 130 ft |
Range at unfavorable condition[4] |
35 m / 115 ft |
Smallest unit displayed |
1 mm / 1/16 in |
∅ laser point at distances |
6 /30 / 60 mm
(10 / 50 / 100 m) |
Tilt measurement |
Measuring tolerance to laser beam[5] |
No |
Measuring tolerance to housing[5] |
No |
Range |
No |
General |
Laser class |
2 |
Laser type |
635 nm, <1 mW |
Protection class |
IP40 |
Automatic laser off |
After 90 seconds |
Automatic power off |
after 180 seconds |
Battery life (2 x AAA) 1.5 V NEDA 24A/IEC LR03 |
Up to 3,000
measurements |
Size (H X W X L) |
116mm Length
53mm Width
33mm Depth |
Weight (with batteries) |
113 g |
Temperature range: Storage Operation |
-25 °C to +70°C
(-13 °F to +158 °F)
0 °C to +40 °C
(32 °F to +104 °F) |
Calibration cycle |
Not applicable |
Maximum altitude |
3000 m |
Maximum relative humidity |
85% at 20 °F to 120°F
(-7 °C to 50 °C) |
Safety |
IEC Standard No. 61010-1:2001
EN60825-1:2007 (Class II) |
EMC |
EN 55022:2010
EN 61000-4-3:2010
EN 61000-4-8:2010 |
[1] Applies for 100 % target reflectivity (white painted wall), low background illumination, 25 °C.
[2] Applies for 10 to 500 % target reflectivity, high background illumination, -10 °C to +50 °C.
[3] Tolerances apply from 0.05 m to 10 m with a confidence level of 95 %. The maximum tolerance may deteriorate to 0.1 mm/m between 10 m to 30 m and to 0.15 mm/m for distances above 30 m.
[4] Applies for 100 % target reflectivity, background illumination between 10'000 lux and 30'000 lux.
[5] After user calibration. Additional angle related deviation of ±0.01° per degree up to ±45° in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by ±0.1°. |
Fluke 62 MAX+ Infrared Thermometer
Specifications |
Temperature Range
|
-30 °C to 650 °C (-22 °F to 1202 °F) |
Accuracy |
±1.0 °C or ±1.0% of reading, whichever is greater
-10 °C to 0 °C: ±2.0
-30 °C to -10 °C: ±3.0 |
Response Time (95%) |
Fluke 62 MAX+ |
<300 ms (95% of reading) |
Spectral Response |
8 to 14 microns |
Emissivity |
0.10 to 1.00 |
Optical Resolution
|
12:1 (calculated at 90% energy) |
Display Resolution |
0.1 °C (0.2 °F) |
Repeatability of Readings |
±0.5% of reading or <±0.5 °C (1 °F), whichever is greater |
Power |
AA battery |
Battery Life |
8 hours with laser and backlight on |
Physical Specifications |
Weight |
255 g (8.99 oz) |
|
Size |
(175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches |
|
Operating Temperature |
0 °C to 50 °C (32 °F to 122 °F) |
|
Storage Temperature |
-20 °C to 60 °C (-4 °F to 140 °F), (without battery) |
|
Operating Humidity |
10 % to 90 % RH non-condensing at 30 °C (86 °F) |
|
Operating Altitude |
2000 meters above mean sea level |
|
Storage Altitude |
12,000 meters above mean sea level |
|
IP Rating |
IP 54 per IEC 60529 |
|
Drop Test |
3 meters |
|
Vibration and Shock |
IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms |
|
EMC |
EN 61326-1:2006 EN 61326-2:2006 |
Standards and Agency Approval
|
Compliance |
EN/IEC 61010-1: 2001 |
|
Laser Safety |
FDA and EN 60825-1 Class II |
|
|
|
|