Testo 890-1 - High-End Infrared Camera with Digital Camera [SKU 0563 0890 V1]

Testo 890-1 - High-End Infrared Camera with Digital Camera [SKU 0563 0890 V1]

Category: Thermal Imager Available
Purchasable on official site
For more information, visit our official website at muser.com.my

Description

testo 890-1 - High-End Infrared Camera with Digital Camera
  Be amazed by the precision and image quality of the testo 890-1 infrared camera. The entry-level model of the testo 890 high-end series successfully meets the thermographic challenges in professional industrial and building thermography. The rotatable, fold-out display enables measurements even in difficult-to-access places.
 
 
Product Description

The entry-level model of the testo 890 high-end series means you are ideally equipped for thermographic challenges in professional industrial and building thermography. This infrared camera's rotatable, fold-out display and its ergonomic rotating handle enable measurements even in difficult-to-access places.

The precision and image quality of the infrared camera will impress you in the following applications:

All the important information about the testo 890-1 infrared camera
The testo 890-1 infrared camera is supplied in a robust case and includes  
Technical Data
 

Infrared image output
Infrared resolution 640 x 480 pixels
Focus auto / manual
Image refresh rate 33 Hz
SuperResolution (Pixel) 1280 x 960 pixels
Geometric resolution (IFOV) 1.13 mrad (Standard lens)
Minimum focus distance 0.1 m (Standard lens)
Field of view 42° x 32°
Thermal sensitivity ˂ 40 mK at +30 °C
Spectral range 7.5 to 14.0 µm
 
Image output visual
Image size 3.1 MP
Minimum focus distance 0.5 m
 
Image presentation
Display type 4.3'' LCD touchscreen with 480 x 272 pixels
Display option IR image / real image
Number of colours 8
Colours 8 (iron, rainbow, cold-hot, blue-red, grey, inverted grey, sepia, Testo)
Video output USB 2.0
 
Measurement
Measuring range -30 to +100°C; 0 to +350 °C (switchable); 0 to +650 °C (switchable)
Accuracy ±2 °C, ±2 % of m.v. (±3 °C of m.v. at -30 to -22 °C)
Reflected temperature manual
Transmission correction Included
 
Measuring function
Surface moisture distribution Not included
Humidity measurement Not included
Solar mode – manual Included
Analysis function 10_measurement_points_isotherms
 
Imager equipment
Digital camera Included
Video measurement up to 3 measurement points
Voice recording Not included
Laser Laser marker
Panorama image assistant Included
Standard lens 42° x 32°
Interface Labview
 
Imager storage
File format image .bmt; export option in .bmp; .jpg; .png; .csv; .xls
File format video .wmv; .mpeg-1
Storage device SD cart 2GB (approx. 1500 - 2000 images)
 
Power supply
Battery type Fast-charging, Li-ion battery can be changed on-site
Operating time 4.5 h
Charging options In instrument / charger (optional)
Mains operation yes
 
Ambient Condition
Storage temperature -30 °C; 60 °C
Operating temperature -15 °C; 50 °C
Air humidity 20 to 80 % RH non-condensing
Housing protection class IP54
Vibration 2G
 
Physical specification
Weight 1,630 g
Dimensions 253 x 132 x 111 mm
Tripod mounting 1/4'' - 20UNC
Housing ABS
 
PC software
System requirements Windows XP (Service Pack 3); Windows Vista; Windows 7 (Service Pack 1); Windows 8; Interface: USB 2.0
 
Standards, tests, warrenty
EU-/EG-guidelines 2004/108/EG
Warranty 2 years
 
 
Applications
 
Checking as part of electrical maintenance
 
In electrical installations or cables, increased temperatures are always an indication of an overload, an imminent malfunction or an existing defect. Testo thermal imagers facilitate evaluation of the heat status of low, medium and high-voltage systems. Thermographic images lead to the early detection of defective components or connections, so that the necessary preventive measures can be introduced in a targeted way. Thermography therefore minimizes dangerous fire risks and prevents costly production downtimes.
 
Typical applications for the thermal imager:
 
Analysis of power distribution systems
 
Avoiding the failure of power distribution systems is absolutely essential due to the far-reaching consequences. Faulty connections on high voltage masts can be particularly critical here. These transitions to high-voltage lines, which sometimes occur at great distances, can only be clearly identified with a sufficiently large detector or a telephoto lens. This is the only way to obtain the necessary degree of detail to enable error-free analysis of the thermal image.
 
 
Analysing building shells at a glance
 
The task of taking thermal images of large buildings poses several challenges for users. Spatial restrictions due to walls, roads or safety zones around neighbouring buildings can make it impossible to capture the measuring object in a single image. In such cases, Testo thermal imagers help users obtain the necessary overview. The panorama image assistant can be used to combine several images of the building shell taken at close range into a single thermal image. Users can therefore identify thermal irregularities at a glance across the entire building shell with a high degree of detail.
 
 
Providing comprehensive energy advice
 
In building thermography, infrared technology is particularly suitable for quick and effective analysis of energy losses in buildings’ heating or air conditioning systems. Thanks to their high temperature resolution, Testo thermal imagers provide detailed images of inadequate insulation and thermal bridges. They are ideal for the recording and documentation of energy losses on outer windows and doors, roller blind casings, radiator niches, in roof structures or the entire building shell. Testo thermal imagers are the perfect measuring tool for comprehensive diagnosis and maintenance uses, and whenever providing energy consultation services.
 
 
Making it possible to see critical temperatures on circuit boards precisely
 
In the field of research and development, thermal imagers are also used for the targeted analysis of temperature distribution, e. g. on circuit boards. Electronic components on circuit boards are getting smaller and smaller – thus increasing the challenges with regard to heat dissipation. Only premium-quality thermal imagers with a really fine geometric resolution are suitable for this task. Analysis of the heating and cooling behaviour over time is also helpful for optimisation and this can be carried out using the Testo thermal imager's video measurement
 
 
 
Downloads
 
Product Brochures

Data sheet testo 890  (PDF, 406 KB)
Product brochure testo 890  (PDF, 5.604 KB)
IRSoft Brochure   (PDF, 1.6 MB)
 
Manuals

Instruction manual testo 890  (PDF, 3.122 kB)
Short manual testo 885/890  (PDF, 1.8 MB)
 
 
Video Demo
 

More detail about Muser Apac Sdn Bhd
Muser Apac Sdn Bhd
Muser Apac Sdn Bhd Testing Instruments Supplier Kuala Lumpur (KL), Malaysia, Monitoring Mapping Systems Supply Selangor, Measuring Equipments Supplies ~ Muser Apac Sdn Bhd
Contact Us flagMalaysia