HI84529-50 Low Range 20 Titrant for Titratable Acidity in Dairy Mini Titrator

HI84529-50 Low Range 20 Titrant for Titratable Acidity in Dairy Mini Titrator

Category: Titrants Out of stock
Purchasable on official site
RM 170.00 For more information, visit our official website at hannamalaysia.com

Description

The HI84529-50 is a 120 mL bottle of titration solution for the Low Range 20  range of the HI84529 Titratable Acidity Mini Titrator for Dairy Analysis.

The HI84529 mini titrator measures acidity in two different ranges (high and low), as well as offering two different sample sizes to choose from when performing a low range measurement (20 and 50). There are three different titrant solutions available based on the range to be used and the weight of the sample, each having a different concentration.

The HI84529-50 is for titration in the low range (0.01 to 0.20 %l.a.) using a 20 mL or 20 g sample. The titrant is pre-standardized, eliminating the need for any volumetric glassware or a analytical balance and making titrations fast, accurate, and simple to perform.

Details

The HI84529-50 is a 120 mL bottle of alkaline titrant solution used for the Low Range 20  range that determines 0.01 to 0.20% lactic acid in dairy products.

The methodology for titratable acidity in dairy products is based on a neutralization reaction of the acids in a sample (e.g., lactic acid) with a base (e.g., sodium hydroxide) to produce water:

H++OH- → H2O

In an ideal solution, the endpoint of an acid titration corresponds stoichiometrically to the complete neutralization of the acids present. The endpoint for this reaction can be determined visually using a color indicator (e.g., phenolphthalein); however, this endpoint becomes very subjective in opaque and colored samples such as milk. The HI84529 removes this issue by titrating to a fixed pH endpoint that is potentiometrically determined by the FC260B half-cell pH electrode and HI5315 half-cell reference electrode.

Replacement reagents required to operate the HI84529 include: 

 

Low Range 20 (LR 20) - %l.a.: 0.01 to 0.20

Low Range 50 (LR 50) - %l.a.: 0.01 to 0.20

High Range 20 (HR 20) - %l.a.: 0.1 to 2.0

Pump calibration standard

HI84529-55

HI84529-55

HI84529-55

Titrant solution

HI84529-50

HI84529-52

HI84529-51

 

 

Specifications

Package bottles
Size 120 mL
Quantity 1
 

More detail about Hanna Instruments (M) Sdn Bhd
Hanna Instruments (M) Sdn Bhd
Hanna Instruments (M) Sdn Bhd Measuring Instruments Selangor, Photometers Supply Penang, Sabah, Test Equipments Supplier Malaysia ~ Hanna Instruments (M) Sdn Bhd
Contact Us flagMalaysia