MW151 MAX pH/ORP/Temp Logging Bench Meter | Milwaukee by Muser

MW151 MAX pH/ORP/Temp Logging Bench Meter | Milwaukee by Muser

Category: pH Meter Available (Qty:4)
Purchasable on official site
RM 2495.00 For more information, visit our official website at muser.com.my

Description

Milwaukee MW151 MAX pH/ORP/Temp Logging Bench Meter
 
 
Description
 
Lab Grade. High Performance. Automated. Tough.
 
The Milwaukee MW151 MAX 3-in-1 pH/OPR/Temp. Logging Portable Bench Meter has won fans around the world with its reliable, fast and simple operation as well as its tough, sleek design with a small lab footprint. The MW151 MAX is accurate to ± 0.002 pH with automatic or manual temperature compensation with a built in dedicated GLP key. Ideal for use by brewers, wine makers, growers, labs, food processing, water treatment and many other applications with challenging pH measurement needs.
 
The Milwaukee MW151 MAX 3-in-1 PRO pH/ORP/Temp Bench Logging Meter is preferred by people testing all types of samples viscus or not, in a variety of applications that cause other pH meters and electrodes to fail. The logging feature allows log-on-demand and log-on-stability features that ensure all readings are accurate and not entered incorrectly. The MA917B/1 Milwaukee double junction electode is refillable and easy to clean. From brewers and wine makers to hydroponic growers, labs and water treatment, the MW151 MAX is your Bench Logging Meter for fast, accurate readings.
 
The Milwaukee MW151 MAX pH Bench meter offers:
 
Accuracy
 
Toughness
 
Low Maintenance
 
Design Features
 
 
Technical Specifications
 

pH Range  -2.00 pH to 20.00 pH / -2.000 pH to 20.000 pH
ORP Range  ±2000.0 mV
Temp. Range  -20.0 to 120.00°C (-4.0 to 248.0°F)
Resolution  0.01 pH / 0.001 pH
Resolution  0.1mV
Resolution  0.1°C / 0.1°F)
Accuracy  ±0.01 pH / ±0.002 pH @ 25°C / 77°F
Accuracy  ±1mV
Accuracy  ±0.4°C |±0.8°F
pH Calibration  up to 5 point automatic pH calibration | 7 standard buffers (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) and two custom buffers
Temperature Compensation  Automatic, -20.0 to 120.0°C (-4.0 to 248.0°F) or manual
pH electrode  MA917B/1 glass, double junction pH electrode (supplied)
Temperature probe  MA831R (included)
Logging Maximum 1,000 samples (stored in up to 100 lots) / on demand, 200 samples on stability, 200 samples/ Interval logging, 1000 logs
PC Connectivity  1 USB Port, 1 micro USB port
Power supply  12VDC, 5 VDC USB Adapter (included)
Battery life  Approx. 8 hours of use
Auto-off  Selectable 5, 10, 30, 60 min. or off
Environment  0 to 50°C / 32 to 122°F; max RH 95%
Dimensions  230 x 160 x 95 mm (9.0 x 6.3 x 3.7 inches)
Weight  0.9 kg / 2.0 lbs.
 
 
Downloads

 
 


More detail about Muser Apac Sdn Bhd
Muser Apac Sdn Bhd
Muser Apac Sdn Bhd Testing Instruments Supplier Kuala Lumpur (KL), Malaysia, Monitoring Mapping Systems Supply Selangor, Measuring Equipments Supplies ~ Muser Apac Sdn Bhd
Contact Us flagMalaysia