YF-78 LCR Multimeter
Application
Easy for holding according to the best design to fit human body engineering, with the optimum inclined view angleFeatures
Specifications
Display unit: 3½digits LCD, with a maximum reading of 1999, units. decimal point and symbol display.
Polarity Indication: when negative value input, automatic display the symbol "-".
Zero reset adjustment: automatic zero reset.
Overload indication:LCD will show a "OL".
Low battery indication: automatic low power test, when battery voltage is lower than work voltage, "BAT" will be shown and you should be ready to replace a new battery.
Sampling rate: 2.5 times/sec.
DCV | ||||
Rnge | Resolution | Accuracy | Input impedance | Overload Protection |
200mV | 100μV | ±(0.5%+1) | 10MΩ | DC 1000V AC 750V rms |
2V | 1mV | ±(0.5%+3) | ||
20V | 10mV | |||
200V | 100mV | |||
1000V | 1V |
ACV | ||||
Range | Resolution | Accuracy 40Hz~500Hz |
Input impedance | Overload Protection |
200mV | 100μV | ±(1.2%+4) | 10MΩ | DC 1000V AC 750V rms |
2V | 1mV | |||
20V | 10mV | |||
200V | 100mV | |||
750V | 1V | ±(1.5%+4) |
DCA | ||||
Range | Resolution | Accuracy | Voltage Burden | Overload Protection |
200μA | 100nA | ±(1.2%+2) | <0.7V | 0.5A/250V fuse |
2mA | 1μA | |||
20mA | 10μA | |||
200mA | 100μA | |||
10A | 10mA | ±(2.5%+2) | <0.3V | 10A/250V fuse |
ACA | ||||
Range | Resolution | Accuracy 40Hz~500Hz |
Voltage Burden | Overload Protection |
200μA | 100nA | ±(1.5%+3) | <0.7V | 0.5A/250V fuse |
20mA | 10μA | |||
200mA | 100μA | |||
10A | 10mA | ±(2.5%+3) | <0.3V | 10A/600V fuse |
Frequency Test (Auto Ranging) | ||||
Range | Resolution | Accuracy | Max.sensitivity | Overload Protection |
2KHz | 1Hz | ±(0.8%+3) | Lo:500mVrms 10K-1MHz 5Vrms 1MHz-20MHz Hi:2Vrms 10-100KHz |
DC/AC 350Vrms |
20KHz | 10Hz | |||
200KHz | 100Hz | |||
2MHz | 1KHz | |||
20MHz | 10KHz |
Diode Test | ||||
Range | Resolution | Measuring Voltage |
Measuring Current |
Overload Protection |
![]() ![]() |
1mV | 3.3Vmax | 0.7mA | DC/AC 500V rms |
Transistor (HFE) Test: | ||||
Range | Measurement Range |
Measuring Voltage |
Measuring Current | Overload Protection |
NPN PNP | 0~1000 | <3.2V | IB "R0.7mA | ───── |
Continuity Test: | ||||
Range | Resolution | Sound level Voltage | open-circuit Protection |
Overload Protection |
![]() ![]() |
0.1Ω | 75Ω below | MAX 3.3V | DC/AC 500V rms |
Resistance Test | ||||
Range | Resolution | Accuracy | Open-circuit Votlage |
Overload Protection |
200Ω | 0.1Ω | ±(1.2%+4) | MAX 3.3V | DC/AC 500V rms |
2KΩ | 1Ω | ±(1.0%+2) | >0.3V | |
20KΩ | 10Ω | |||
200KΩ | 100Ω | |||
2MΩ | 1KΩ | |||
20MΩ | 10KΩ | ±(2%+5) |
Capacitance Test | ||||
Range | Resolution | Accuracy | Measuring Frequency |
Overload Protection |
2nF | 1pF | ±(5%+10) | "R200Hz/1.5sec | 0.5A/250V fuse |
20nF | 10pF | |||
2μF | 1nF | |||
20μF | 10nF | |||
2000μF | 1μF | "R2Hz/8sec |
Inductance Test | ||||
Range | Resolution | Accuracy | Open-circuit Voltage |
Overload Protection |
2mH | 1μ | ±(5%+10) | "R1000Hz | 0.5A/250V Fuse |
20mH | 10μ | |||
200mH | 100μ | "R200HZ | ||
2H | 1mH | |||
20H | 10mH |