Deskripsyon
testo 320 - Super Efficient Flue Gas Analyzer
-
Six applications, one device: flue gas, flue draft, pressure, gas leak detection, CO ambient air and pressure difference measurements
-
Integrated flue gas sensors with temperature sensor included; ultra-fine pressure sensors and a wide range of other sensors, ports and probes optional
-
Rugged, high-quality design, high-resolution, multi-color display, self-explanatory menu guide
-
TÜV-tested according to EN 50379, Parts 1-3 and 1st BImSchV
Temperature measurements at radiators; flue gas parameter and pressure measurements at burners; CO measurements in the ambient air: the testo 320 allows you to carry out all measurements in and around heating systems with only one measuring device.
Product Description
The testo 320 flue gas analyzer is a trusty and reliable companion for all those people who specialise in installing, inspecting and servicing heating systems. The high-quality, professional all-rounder is easy to use and allows you to carry out all measurements in and around heating systems with only one device. The testo 320’s special rugged design means that it is excellently equipped to stand up to the rough and tumble of daily use.
A set of easy-to-follow, self-explanatory, country-specific menus guide you safely through all the measurements. The readings are all presented graphically on a high-resolution, crisp color display for use in all lighting conditions. The user-friendly analyzer also has a memory for up to 500 readings.
Moreover the flue gas analyzer is TÜV-tested according to EN 50379, Parts 1-3 and 1st BImSchV.
The testo 320 flue gas analyzer – facts and features
The testo 320 flue analyzer comes with one sensor for O2 and additionally you can order a CO sensor (separate product). The flue gas analyzer then calculates the relevant flue gas values, i.e. CO2 value, efficiency and flue gas loss.
There is also wide range of optional sensors for you to choose from. These include multiple-hole, edge crack and flexible flue gas sensors as well as an ultra-fine flue gas pressure sensor which allows you to perform draft and gas pressure measurements parallel to the other measurements.
Areas of application for the testo 320 flue gas analyzer
Six applications. One device:
-
flue gas measurements
-
flue draft measurements
-
gas flow and static gas pressure
-
gas leak detection
-
CO ambient air measurements
-
temperature difference measurements
Allows you to monitor and check heating environments, radiators and burners easily and reliably.
Delivery Scope
testo 320 flue gas analyzer, O2 sensor.
Technical Data
Flue gas CO (with H₂-compensation) |
Measuring range |
0 to 8000 ppm |
Accuracy |
±10 ppm or ±10 % of mv (0 to 200 ppm)
±20 ppm or ±5 % of mv (201 to 2000 ppm)
±10 % of mv (2001 to 8000 ppm) |
Resolution |
1 ppm |
Reaction time t₉₀ |
< 40 s |
Flue gas COlow |
Measuring range |
0 to 500 ppm |
Accuracy |
±2 ppm (0 to 39.9 ppm)
±5 % of mv (40 to 500 ppm) |
Resolution |
0.1 ppm |
Reaction time t₉₀ |
< 40 s |
Flue gas Draught |
Measuring range |
-9.99 to +40 hPa |
Accuracy |
±0.02 hPa or ±5 % of mv (-0.50 to +0.60 hPa)
±0.03 hPa (+0.61 to +3.00 hPa)
±1.5 % of mv (+3.01 to +40.00 hPa) |
Temperature |
Measuring range |
-40 to +1200 °C |
Accuracy |
±0.5 °C (0 to +100.0 °C)
±0.5 % of mv (Remaining Range) |
Resolution |
0.1 °C (-40 to +999.9 °C)
1 °C (> +1000 °C) |
Flue gas degree of effectivity, Eta (calculated) |
Measuring range |
0 to 120 % |
Resolution |
0.1 % |
Flue gas loss (calculated) |
Measuring range |
0 to 99.9 % |
Resolution |
0.1 % |
Flue gas CO₂ calculation (calculated from O₂) |
Measuring range |
Display range 0 to CO₂ max |
Accuracy |
±0.2 Vol.% |
Resolution |
0.1 Vol.% |
Pressure measurement |
Measuring range |
0 to +300 hPa |
Accuracy |
±0.5 hPa (0.0 to 50.0 hPa)
±1 % of mv (50.1 to 100.0 hPa)
±1.5 % of mv (Remaining Range) |
Resolution |
0.1 hPa with fine draught option 0.01 hPa |
Flue gas CO (without H₂-compensation) |
Measuring range |
0 to 4000 ppm |
Accuracy |
±20 ppm (0 to 400 ppm)
±5 % of mv (401 to 2000 ppm)
±10 % of mv (2001 to 4000 ppm) |
Resolution |
1 ppm |
Ambient CO |
Measuring range |
0 to 500 ppm |
Accuracy |
±5 ppm (0 to 100 ppm)
±5 % of mv (> 100 ppm) |
Resolution |
1 ppm |
with CO probe 0632 3331
Ambient CO₂ |
Measuring range |
0 to 1 Vol.%
0 to 10000 ppm |
Accuracy |
±75 ppm or ±3 % of mv (0 to 5000 ppm)
±150 ppm or ±5 % of mv (5001 to 10000 ppm) |
with ambient CO₂ probe 0632 1240
Gas leak measurement for combustible gases (via gas leak detection probe) |
Measuring range |
0 to 10000 ppm CH₄ / C₃H₈; Display range |
Accuracy |
Signal optical display (LED) audible signal via buzzer |
Reaction time t₉₀ |
< 2 s |
with gas leak detection probe 0632 3330
General technical data |
Dimensions |
240 x 85 x 65 mm |
Operating temperature |
-5 to +45 °C |
Warranty |
Instrument: 24 months; Probe: 24 months; Gas sensors: 24 months; rechargeable battery: 12 months |
Display size |
240 x 320 pixels |
Display function |
Colour graphic display |
Power supply |
Battery: 3.7 V / 2,400 mAh; Mains unit: 6 V / 1.2 A |
Maximum |
500 Measurement values |
Storage temperature |
-20 to +50 °C |
Weight |
573 g |
Applications
Ambient CO measurement in the heated environment
Carbon monoxide (CO) is a colourless, odourless and taste-free gas, but also poisonous. It is produced during the incomplete combustion of substances containing carbon (oil, gas, and solid fuels, etc.). If CO manages to get into the bloodstream through the lungs, it combines with haemoglobin thus preventing oxygen from being transported in the blood; this in turn will result in death through suffocation. This is why it is necessary to regularly check CO emissions at the combustion points of heating systems and the surroundings.
Measuring the flue gas parameters of the burner (CO, O2, and temperature, etc.)
The flue gas measurement for a heating system helps to establish the pollutants released with the flue gas (e.g. carbon monoxide CO or carbon dioxide CO2) and the heating energy lost with the warm flue gas. In some countries, flue gas measurement is a legal requirement. It primarily has two objectives:
-
Ensuring the atmosphere is contaminated as little as possible by pollutants; and
-
energy is used as efficiently as possible.
Stipulated pollutant quantities per flue gas volume and energy losses must never be exceeded. Measurement in terms of results required by law takes place during standard operation (every performance primarily using the appliance). Using a Lambda probe (single hole or multi-hole probe), the measurement is taken at the centre of flow in the connecting pipe (in the centre of the pipe cross-section, not at the edge) between the boiler and chimney/flue. The measured values are recorded by the flue gas analyzer and can be logged either for print out or transfer to a PC at a later stage.
Measurement is taken by the installer at commissioning, and if necessary four weeks later by the flue gas inspector/chimney sweep, and then at regular intervals by the authorised service engineer.
Measuring pressure on burners (nozzle pressure, gas flow pressure, etc.)
Standard readings taken during services of domestic heating systems include checking the gas pressure on the burners. This involves measuring the gas flow pressure and gas resting pressure. The flow pressure, also called supplied pressure, refers to the gas pressure of the flowing gas and resting pressure of the static gas. If the flow pressure for gas boilers is slightly outside the 18 to 25 mbar range, adjustments must not be made and the boiler must not be put into operation. If put into operation nonetheless, the burner will not be able to function properly, and explosions will occur when setting the flame and ultimately malfunctions; the burner will therefore fail and the heating system will shut down.
Measuring temperatures on radiators
When measuring the temperature on radiators, the flow and return temperatures are recorded in particular and assessed by the tradesman. The flow temperature is defined as the temperature of a thermal transfer medium (e.g. water) that the system is supplied with. The temperature of the medium flowing out of the system is accordingly called the return temperature. To prevent losses within the heat distribution system and achieve a better level of efficiency in modern, heating technology, spot recording of flow and return temperatures is necessary at certain radiator pipes or screw fittings. Implementation of relevant measures ultimately leads to hydraulic adjustment on the basis of knowledge about the flow and return temperatures. This defines a procedure with which every radiator or heating circuit of a flat radiator within a heating system is supplied at a set flow temperature with the precise amount of heat needed to achieve the ambient temperature required for the individual rooms. Flawed operating conditions will result in considerable excess consumption of electricity and heating energy.
Downloads
Product Brochures
Product brochure testo 320 (PDF, 884.7 kB)
Manuals
Instruction manual testo 320 (application/pdf, 7.935 KB)
Tingnan ang karagdagang mga detalye tungkol sa Muser Apac Sdn Bhd