Testo 320 Basic - Compact Flue Gas Analyzer [SKU 0632 3223]

Testo 320 Basic - Compact Flue Gas Analyzer [SKU 0632 3223]

Kategorya: Flue Gas Analyzer Magagamit
Maaaring Bumili sa Opisyal na Website
Para sa karagdagang impormasyon, bisitahin ang aming opisyal na website sa muser.com.my

Deskripsyon

testo 320 Basic - Compact Flue Gas Analyzer
 
Flue gas measurement on heating systems with a compact flue gas analyzer for oil and gas: the testo 320 basic features all the essential functions for carrying out flue gas analysis, flue draught and pressure measurements. The flue gas analyzer is impressive because it is easy to operate (featuring user-friendly menu guidance) and reliable (2-year warranty for the instrument, probe, O2/CO sensor).
 
 
Product Description
 
You will find the testo 320 basic flue gas analyzer a reliable tool for carrying out installation and maintenance work on heating systems. A compact flue gas analyzer, it can be used to measure flue gas, draught, pressure, ambient CO and differential temperature.

Self-explanatory menu guidance makes operation simpler and makes your job easier. Thanks to the high resolution colour display, the readings are easy to read off even when the light is poor. The flue gas analyzer can store up to 20 measurement protocols. It is possible to export the measurement protocols in Excel optionally via mini-USB.

Quality that you can depend on: the testo 320 basic flue gas analyzer is TÜV-tested according to EN 50379, Part 1-3 and to 1st German Federal Immission Control Ordinance (BImSchV), Part 1-2. When you purchase the flue gas analyzer, you get a 2-year warranty (for the instrument, probe, O2/CO sensor).

 
 
testo 320 basic flue gas analyzer: compact and powerful
 
Fields of application for the testo 320 basic flue gas analyzer
Note: to carry out the measurement, you need a compact or modular flue gas probe (can be ordered separately)
 
 
Delivery Scope
 
testo 320 basic flue gas analyzer with O2/CO sensor without H2 compensation, including calibration protocol, colour graphic display. 
 
 
Technical Data
 

Flue gas O
Measuring range 0 to 21 Vol.%
Accuracy ±0.2 Vol.%
Resolution 0.1 Vol.%
Reaction time t₉₀ < 20 s
 
Flue gas Draught
Measuring range -9.99 to +40 hPa
Accuracy ±0.02 hPa or ±5 % of mv (-0.50 to +0.60 hPa)
±0.03 hPa (+0.61 to +3.00 hPa)
±1.5 % of mv (+3.01 to +40.00 hPa)
Resolution 0.01 hPa
 
Temperature
Measuring range -40 to +1200 °C
Accuracy ±0.5 °C (0 to +100.0 °C)
±0.5 % of mv (Remaining Range)
Resolution 0.1 °C (-40 to +999.9 °C)
1 °C (> +1000 °C)
 
Flue gas degree of effectivity, Eta (calculated)
Measuring range 0 to 120 %
Resolution 0.1 %
 
Flue gas loss (calculated)
Measuring range 0 to 99.9 %
Resolution 0.1 %
 
Flue gas CO calculation (calculated from O)
Measuring range 0 to CO max (Display range)
Accuracy ±0.2 Vol.%
Resolution 0.1 Vol.%
Reaction time t₉₀ 40 s
 
Pressure measurement
Measuring range 0 to +300 hPa
Accuracy ±0.5 hPa (0.0 to 50.0 hPa)
±1 % of mv (50.1 to 100.0 hPa)
±1.5 % of mv (Remaining Range)
Resolution 0.1 hPa
 
Flue gas CO (without H-compensation)
Measuring range 0 to 4000 ppm
Accuracy ±20 ppm (0 to 400 ppm)
±5 % of mv (401 to 2000 ppm)
±10 % of mv (2001 to 4000 ppm)
Resolution 1 ppm
Reaction time t₉₀ < 60 s
 
Ambient CO
Measuring range 0 to 4000 ppm
Accuracy ±20 ppm (0 to 400 ppm)
±5 % of mv (401 to 2000 ppm)
±10 % of mv (2001 to 4000 ppm)
Resolution 1 ppm
Measuring rate < 60 s
 
General technical data
Dimensions 240 x 85 x 65 mm
Operating temperature -5 to +45 °C
Protection class IP40
Warranty Instrument: 24 months; Probe: 24 months; Gas sensors: 24 months; rechargeable battery: 12 months; Thermocouple 12 months
Display size 240 x 320 pixels
Display function Colour graphic display
Power supply Battery: 3.7 V / 2,400 mAh; Mains unit: 5 V / 1 A
Storage temperature -20 to +50 °C
Weight 573 g
 
 
Applications
 
Measuring the flue gas parameters of the burner (CO, O2, and temperature, etc.)
The flue gas measurement for a heating system helps to establish the pollutants released with the flue gas (e.g. carbon monoxide CO or carbon dioxide CO2) and the heating energy lost with the warm flue gas. In some countries, flue gas measurement is a legal requirement. It primarily has two objectives:

 
Stipulated pollutant quantities per flue gas volume and energy losses must never be exceeded. Measurement in terms of results required by law takes place during standard operation (every performance primarily using the appliance). Using a Lambda probe (single hole or multi-hole probe), the measurement is taken at the centre of flow in the connecting pipe (in the centre of the pipe cross-section, not at the edge) between the boiler and chimney/flue. The measured values are recorded by the flue gas analyzer and can be logged either for print out or transfer to a PC at a later stage.
 
Measurement is taken by the installer at commissioning, and if necessary four weeks later by the flue gas inspector/chimney sweep, and then at regular intervals by the authorised service engineer.
 
 
Downloads
 
Product Brochures

Product brochure testo 320  (PDF, 884.7 kB)
 
Manuals

Instruction manual testo 320  (application/pdf, 7.935 KB)
 

Tingnan ang karagdagang mga detalye tungkol sa Muser Apac Sdn Bhd
Muser Apac Sdn Bhd
Muser Apac Sdn Bhd Testing Instruments Supplier Kuala Lumpur (KL), Malaysia, Monitoring Mapping Systems Supply Selangor, Measuring Equipments Supplies ~ Muser Apac Sdn Bhd