HI5313 PEI Body Reference Electrode for FC301B

HI5313 PEI Body Reference Electrode for FC301B

Kategorya: ISE Magagamit (Jml:1)
Maaaring Bumili sa Opisyal na Website
RM 811.00 Para sa karagdagang impormasyon, bisitahin ang aming opisyal na website sa hannamalaysia.com

Deskripsyon

The HI5313 is a PEI body, refillable, single junction, half-cell reference electrode with a 4 mm banana connector. This electrode has a single ceramic junction in the outer reference cell and is made for use in temperatures ranging from -5 to 60°C.

This design consideration is made for use with the FC301B fluoride half-cell ion selective electrode.

Details

Hanna Instruments offers a wide variety of pH electrodes that are designed for many different applications. The type of glass used, body material, type of junction, type of reference and electrolyte used are just some of the design considerations.

The HI5313 uses a PEI body, single ceramic junction and stable gel electrolyte.



PEI Body

The body of the HI5313 is composed of polyetherimide (PEI) resin. The PEI body is suitable for a wide range of applications and excels in field measurements due to its durability. The shielding around the spherical glass tip minimizes breakage due to accidental bumping or dropping of the electrode. The PEI plastic is a high quality plastic that is chemically resistant to many aggressive chemicals.

 



Ceramic Junction

The outer junction of an electrode, also known as a salt bridge, is necessary component of the electrical circuit. The movement of ions must flow through the junction for a steady reading. The outer reference has a single ceramic frit. The ceramic is a porous material that has a flow rate of 15-20 μL/hour. Other junction types are available with higher flow rates and made with different materials.

 



4 mm Connector

The HI5313 uses a 4 mm banana connector. This type of connector is easily plugged into the reference input on suitable meters. Other type of connectors include BNC, DIN, screw type, T-type, and 3.5mm to name a few. These types of connectors tend to be proprietary for a particular type of meter and are not interchangeable.


 

 

Specifications

Body Material PEI
Reference single, Ag/AgCl
Junction / Flow Rate ceramic
Electrolyte gel (KCl 1M + AgCl)
Max Pressure 0.1 bar
Diameter 12 mm
Body Length / Overall Length 120 mm / 163.5 mm
Recommended Operating Temperature -5 to 60°C (23 to 140°F)
Cable 1 m (3.3')
Connection banana
Applications samples with suspended solids, titrations

 




 

Tingnan ang karagdagang mga detalye tungkol sa Hanna Instruments (M) Sdn Bhd
Hanna Instruments (M) Sdn Bhd
Hanna Instruments (M) Sdn Bhd Measuring Instruments Selangor, Photometers Supply Penang, Sabah, Test Equipments Supplier Malaysia ~ Hanna Instruments (M) Sdn Bhd