Analog section | |
Excitation voltage | DC5V±5% Output current:90mA Remote sense type (Up to 6 350Ω load cells can be connected in parallel) |
---|---|
Signal input range | -2.5 to +5.1mV/V |
Zero adjustment range | Automatic adjustment by digital processing -2.5 to +2.0mV/V |
Span adjustment range |
Automatic adjustment by digital processing 0.02 to +3.0mV/V |
Linearization function | Up to three point multi-point calibration is possible |
Min. input sensitivity | 0.15μV/count |
Accuracy | Non-linearity: within 0.01%FS Zero drift: 0.0002%FS/℃ Typ Gain drift: 1ppm/℃ Typ |
Filter | Digital low-pass filter 0.1 to 300.0 Hz Moving average filter OFF, 2 to 512 times |
A/D converter | Speed: 300 times/sec., 1200 times/sec. Resolution: 24bit binary |
Display section | |
Display Unit | 7-segment LCD display Main display: 8 digit(14.4mm character height), Sub-display: 20 digit (4.3mm character height) |
---|---|
Display value | 5 digit sign: negative display at the highest digit (Up to 6 digits) |
Unit | None / kg / g / t / lb / N |
Decimal point | 0, 0.0, 0.00, 0.000 |
Weight errors | “LOAD”: sensor signal level is above the signal input range, “-LOAD”: the sensor signal level is below the signal input range, “OFL1”: the Net weight is over the limit, “OFL3”: the GROSS weight is over the limit |
Display frequency | 1, 3, 6, 13 or 25 times/sec. |
Status display | SP1 / SP2 / SP3 / COMPLETE / TARE ON / NET / OUT1 / OUT2 |
Setting section | |
Setting method | By operating the membrane keys or through interface |
---|---|
Memory of set value | Default settings: stored in NOV.RAM (non-volatile RAM) Time: backed up by lithium battery Other setting values: stored in F-RAM (non-volatile RAM) |
Protection of set value | Settings can be protected with the software LOCK |
Setting item | – Upper limit / Lower limit / Near zero / Set point 1 / Set point 2 / Compensation / Over / Under / Final – Comparison inhibit time 1 / Judging time / Complete output time / Compensation Feeding Time / Number of times for AZ / Number of times for judging / Auto free fall compensation regulation values / Comparison inhibit time 2 / Preset tare value – Weighing function 1 / Weighing function 2 / Weighing function 3 / Sequence mode / Key invalid-LOCK / Discharging Time / Motion detection(Period – Range) / Zero tracking (Period) / Zero tracking (Range) – Balance weight value / Minimum scale division / NET weight over / GROSS weight over /DZ limitation value / Display selection / Gravitational acceleration / Sub-display mode /Sub-display selection – D/A output mode / D/A zero scale adjustment / D/A full scale adjustment / RS-232C/RS-485 setting / RS-232C/RS-485 ID / Transmission delay time / CC-Link I/F setting / CC-Link station number setting / Setting LOCK – Input Signal selection 1 / Input Signal selection 2 / Input Signal selection 3 / Output Signal selection 1 /Output Signal selection 2 / Output Signal selection 3 / Output Signal selection 4 / Status display selection / Sampling speed – Total count / SP0 / Total comparison mode / Target total weight (high 4) /Target total weight (under 5) / Total SP1 (high 4) / Total SP1 (under 5) – SD card command 1 / SD card command 2 / Time and Date / Auto adjustment filter / Digital low pass filter / Moving average filter / Extended function selection 1 / Extended function selection 2 / Total weight control function – Average weight value / Maximum weight value / Minimum weight value /General standard deviation / Sample standard deviation / Number of data / Latest data /Maximum-Minimum / Option display – Span calibration / Equivalent span calibration / Equivalent zero calibration / Linearize calibration 1 / Linearization calibration 2 / Linearization calibration 3 / Linearization Calibration / Calibration Point Confirmation / Password / Zero Calibration |