FC1000 is the weighing indicator with various features such as the white LCD main and sub display, dust and drip protection (Equivalent to IP65), accumulation function, data recording on SD Card, and high-speed A/D conversion rate of 1.2kHz.

 



SD card slot
You can write and read setting parameters from SD cards, while recording weighing results & data when abnormalities occur.
 
■ Calibration value & Error logs are automatically recorded
 You can identify the indications of faulty load cells and replacement timing.
 Date & time of errors occurred can be displayed, as well as the record of how the errors are made (through key control, communication, I/O, etc).
 
■ Data recording of weighing results
 Monitor management of raw material, equipment operation rate and so on.
 Long-term trend can be observed as well.
 
■ Restore setting parameters with just one touch
 0鸜ou can copy setting parameters to another replaced FC1000.
 0鸐ultiple FC1000s can use the exact same settings.
 0鸜ou can restore the initial setting when you first install FC1000. (It will be saved as initial value separately from the setting parameters).

Depth of 99mm
Miniaturization of control panel & panel space saving.
 
High performance filter & Auto filter adjustment
With combination of low pass filter (0.1 to 300Hz) which corresponds to various vibration and moving average filter (OFF, 2 to 512) that is effective for periodic vibration, automatic searching for optimal value with accuracy and stability can be achieved. (You can manually adjust settings too).
 
 
Minus compensation
High-pressure liquid filling & powder feeding can be done.

Equivalent to IP65 protection
By placing the rubber seal when mounting on the panel, the front panel can be protected from moisture and dust damage.
 
High sampling rate & resolution
High performance digital low-pass filter can be adjusted at 0.1Hz increment. As it is resistant to vibration, measurement can be performed quickly and precisely.
 
Load cell signal level display (-2.51mV/V to 5.1mV/V)
The output signal level of load cell can be displayed in mV/V for monitor purpose.
Malfunction indicator or faulty sensor can be differentiated easily.
 
Total weight control function
The batch weighing with a low capacity scale enables the fast and accurate measurement of larger total weight.

Bright white LCD display with the useful 20 digits sub display
The sub display can be used to show the cumulative weight, code/preset number, etc….

 
6 digit display
24 bit A/D convertor enables 6 digit display.
 
Memory for 32 weight settings
32 different weight settings can be saved in the memory and selected through I/O or interface.
Batch weighing can be performed easily.
 
Equivalent input calibration
Theoretical calibration can be performed easily by registering the capacity and rated output of load cells.
 
Multipoint calibration (linearization)
Three additional points can be defined in the middle between zero and span for better linearity.
Even though the scale has poor linearity, it can be corrected to be a highly accurate scale.


 
Analog section
Excitation voltage DC5V±5% Output current:90mA
Remote sense type (Up to 6 350Ω load cells can be connected in parallel)
Signal input range -2.5 to +5.1mV/V
Zero adjustment range Automatic adjustment by digital processing -2.5 to +2.0mV/V
Span adjustment range

Automatic adjustment by digital processing 0.02 to +3.0mV/V

Linearization function Up to three point multi-point calibration is possible
Min. input sensitivity 0.15μV/count
Accuracy Non-linearity: within 0.01%FS
Zero drift: 0.0002%FS/℃ Typ
Gain drift: 1ppm/℃ Typ
Filter Digital low-pass filter 0.1 to 300.0 Hz
Moving average filter OFF, 2 to 512 times
A/D converter Speed: 300 times/sec., 1200 times/sec.
Resolution: 24bit binary
 
Display section
Display Unit 7-segment LCD display
Main display: 8 digit(14.4mm character height),
Sub-display: 20 digit (4.3mm character height)
Display value 5 digit sign: negative display at the highest digit (Up to 6 digits)
Unit None / kg / g / t / lb / N
Decimal point 0, 0.0, 0.00, 0.000
Weight errors “LOAD”: sensor signal level is above the signal input range,
“-LOAD”: the sensor signal level is below the signal input range,
“OFL1”: the Net weight is over the limit,
“OFL3”: the GROSS weight is over the limit
Display frequency 1, 3, 6, 13 or 25 times/sec.
Status display SP1 / SP2 / SP3 / COMPLETE / TARE ON / NET / OUT1 / OUT2
 
Setting section
Setting method By operating the membrane keys or through interface
Memory of set value Default settings: stored in NOV.RAM (non-volatile RAM)
Time: backed up by lithium battery
Other setting values: stored in F-RAM (non-volatile RAM)
Protection of set value Settings can be protected with the software LOCK
Setting item – Upper limit / Lower limit / Near zero / Set point 1 / Set point 2 / Compensation / Over / Under / Final
– Comparison inhibit time 1 / Judging time / Complete output time / Compensation Feeding Time / Number of times for AZ / Number of times for judging / Auto free fall compensation regulation values / Comparison inhibit time 2 / Preset tare value
– Weighing function 1 / Weighing function 2 / Weighing function 3 / Sequence mode / Key invalid-LOCK / Discharging Time / Motion detection(Period – Range) / Zero tracking (Period) / Zero tracking (Range)
– Balance weight value / Minimum scale division / NET weight over / GROSS weight over /DZ limitation value / Display selection / Gravitational acceleration / Sub-display mode /Sub-display selection
– D/A output mode / D/A zero scale adjustment / D/A full scale adjustment / RS-232C/RS-485 setting / RS-232C/RS-485 ID / Transmission delay time / CC-Link I/F setting / CC-Link station number setting / Setting LOCK
– Input Signal selection 1 / Input Signal selection 2 / Input Signal selection 3 / Output Signal selection 1 /Output Signal selection 2 / Output Signal selection 3 / Output Signal selection 4 / Status display selection / Sampling speed
– Total count / SP0 / Total comparison mode / Target total weight (high 4) /Target total weight (under 5) / Total SP1 (high 4) / Total SP1 (under 5)
– SD card command 1 / SD card command 2 / Time and Date / Auto adjustment filter / Digital low pass filter / Moving average filter / Extended function selection 1 / Extended function selection 2 / Total weight control function
– Average weight value / Maximum weight value / Minimum weight value /General standard deviation / Sample standard deviation / Number of data / Latest data /Maximum-Minimum / Option display
– Span calibration / Equivalent span calibration / Equivalent zero calibration / Linearize calibration 1 / Linearization calibration 2 / Linearization calibration 3 / Linearization Calibration / Calibration Point Confirmation / Password / Zero Calibration