H3C S9800

H3C S9800

Kategorya: Aggregation Switch Magagamit
Para sa karagdagang impormasyon, bisitahin ang aming opisyal na website sa 1stopsecuritysystems.com

Deskripsyon

H3C S9800 DataCenter Switches
The H3C S9800 DataCenter Cloud High Density Switch Series is designed for cloud services data centers. It deploys industry leading CLOS architecture, providing highest switching performance and most comprehensive data centre features of this kind in the industry.

S9800 is industry’s highest port density high-end switch per RU. S9810 can provide upto 480 wire speed 10G ports or 120 wire speed 40G ports, delivering super high density 10GE, 40GE and even 100G port density. In order to fulfill data centre cloud virtualization requirements, S9800 switch series supports IRF2 (Intelligent Resilient Framework version 2) and MDC (Multitenant Devices Context). At the same time, S9800 switch series uses latest Comware V7 platform, which is a modular design and reliable, highly efficient and open operating system.

The S9800 switch series includes S9804 and S9810, two models which meet various port density and performance requirements. The S9800 switch series can work with H3C routers, switches, security devices, IMC, and H3Cloud to provide wide variety solutions.

 

Features:
Advanced CLOS multi-grade multi-plane switching architecture

Adopt CLOS multi-grade multi-plane architecture, providing industry leading port density

S9810 can provide max.480 line-speed 10G interfaces or 120 line-speed 40G interface per chassis, fulfilling high density 10G, 40G and future 100G application

Virtualization technologies - IRF2

IRF2 can virtualize up to four S9800 switche into one logical IRF fabric. IRF2 delivers the following benefits:

High Availability (HA) - Patented hot standby technology to provide data backup and non-stop forwarding on the control plane and data plane. This improves availability and performance, eliminates single-point failures, and ensures service continuity.

Distribution - Multi-chassis link aggregation to enable load sharing and backup over multiple uplinks, improving redundancy and link utilization.

Easy Management - A single IP address to manage the whole IRF fabric, which simplifies device and topology management, improving operating efficiency, and lowering network maintenance cost.

Virtualization technologies – MDC

MDC virtualizes one S9800 switch into multiple logical switches, enabling multiple services to share one core switch. The 1:N virtualization maximizes switch utilization, reduces network TCO, and ensures secure isolation of services.

DC-class HA

BFD for VRRP/BGP/IS-IS/RIP/OSPF/RSVP/static routing.

NSR/GR for OSFP/BGP/IS-IS/RSVP.

1+1 redundancy for fan trays.

N+M redundancy for power modules.

S9810 1+1 redundancy for control engines.

Multi-level security protection

The S9800 switch series use QoS policies to filter and limit traffic from data plane to control plane. During a DoS attack, the switch can identify and protect important packets and discard attack packets, ensuring normal operation.

Supports a large numbers of ACLs while ensuring line-speed forwarding. ACLs can identify and control L2/IPv4/IPv6/MPLS traffic by using combinations of packet fields.

Comprehensive maintenance and monitoring

Online state monitoring - Uses a dedicated engine to monitor the state of switch fabric modules, backplane channels, service communication channels, key chips, and storage.

Card isolation - Isolates specified cards from the forwarding plane. The isolated cards still work on the control plane, allowing the user to perform management operations such as real-time diagnosis and CPLD upgrade on the isolated cards without affecting system operation.

Ethernet OAM provides multiple device-level and network-level fault detection methods.

DC-oriented features

Low latency, suitable for high performance data centre

Distributed ingress buffers (100 ms) to accommodate burst traffic in data centers

Large capacities for storing ARP/ND, suitable for large scale flat data centre

Advanced flow control and back pressure mechanism for new generation data centre lossless design

FCOE - Integrates heterogeneous LANs and storage networks in data centers. FCOE and CEE integrate data, computing, and storage networks in data centers, reducing the costs for building and expanding data centers

Green

Intelligent EMS engine system - Provides smart power management that supports sequential power-on and power-off and device status check. Sequential power-on and power-off reduces power impulse and electromagnetic radiation, and increases the lifetime of the device. Additionally, device status checks can isolate faulty and idle cards to reduce power consumption.

Smart fan management - Collects fan temperature, calculates fan speed, and assigns the calculated speed to the fan tray. In addition, it detects fan speeds, fault alarms, and performs speed adjustment based on configurations and area, reducing power consumption and noise, increasing the fan's lifetime.

Internal interface monitoring - Automatically shuts down unused internal interfaces to reduce power consumption.

RoHS compliance - The S9800 series meets the EU RoHS safety standards.


Specification

Item S9804 S9810
Switching capacity 5.88-17.66Tbps
Throughput 2400-6000Mpps
LPU slots 4 10
Redundancy power modules, and fan trays Redundant MPUs, power modules, and fan trays
Ethernet IEEE 802.1Q
DLDP
LLDP
Static MAC configuration
Limited MAC learning
Port mirroring and traffic mirroring
Port aggregation, port isolation, and port mirroring
IEEE 802.1D (STP)/802.1w (RSTP)/802.1s (MSTP)
IEEE 802.3ad (dynamic link aggregation), static port aggregation, and multi-chassis link aggregation
IPv4 Static routing, RIP, OSPF, IS-IS, and BGP4
VRRP, VRRP load balancing
ECMP
Policy-based routing
Routing policy
GRE, IPv4 in IPv4 tunneling
IPv6 IPv4/IPv6 dual stack
IPv6 static routing, RIPng, OSPFv3, IS-ISv6, and BGP4+
VRRPv3 and VRRPv3 load balancing
ND and PMTUD
Pingv6, Tenetv6, FTPv6, TFTPv6, DNSv6, and ICMPv6
IPv4-to-IPv6 transition technologies, such as IPv6 manual tunnel, 6to4 tunnel, ISATAP tunnel, GRE tunnel, and auto IPv4-compatible IPv6 tunnel
ECMP
Policy-based routing
Policy routing
Multicast PIM-DM, PIM-SM, PIM-SSM, MSDP, MBGP, and Any-RP
IGMP V1/V2/V3 and IGMP V1/V2/V3 snooping
PIM6-DM, PIM6-SM, and PIM6-SSM
MLD V1/V2 and MLD V1/V2 snooping
Multicast policies and Multicast QoS
Multicast replication on switching fabrics and service cards
MPLS VPN P/PE function in accordance with RFC2547bis
Three inter-AS MPLS VPN modes: Option 1, Option 2 and Option 3
Hierarchy of PE (HoPE)
Multi-role host
VLL
VPLS/H-VPLS
Distributed multicast VPN
ACL Standard and extended ACLs
Ingress and egress ACLs
VLAN ACL
Global ACLs
QoS Diff-Serv QoS
SP/SDWRR
Traffic policing with 1K granularity
Traffic shaping
Congestion avoidance
Priority marking and remarking
802.1p, TOS, DSCP, and EXP priority mapping
VOQ
SDN/OPENFLOW Support OPENFLOW 1.3 standard
Support multi-controller (EQUAL mode, standby mode)
Support multi-table line
Support Group table
Support Meter
VXLAN Support VXLAN L2 switching
Support VXLAN L3 switching
Support VXLAN gateway
Support IS-IS+ENDP VXLAN distributed control plane
Support OpenFlow+Netconf VXLAN centralized control plane
HA FFDR detection engine
1+1 redundancy or key components such as MPUs (Only for S9810) and power modules
Passive backplane
Hot swapping for all components
Real-time data backup on active/standby MPUs (Only for S9810)
Hot patching
NSR/GR for OSFP/BGP/IS-IS/RSVP
Port aggregation and multi-card link aggregation
BFD for VRRP/BGP/IS-IS/OSPF/RSVP/static routing, with a failover time less than 50 millisecond
IP FRR and TE FRR with a switchover time less than 50 millisecond
Security Hierarchical user management and password protection
SSHv2
FTP login controlled by IP addresses
Basic and advanced ACLs for packet filtering
Protection against ARP, unknown multicast packets, broadcast packets, unknown unicast packets, local network scanning packets, packets with TT=1, and protocol packets attacks
MAC address control and IP+MAC binding
uRPF
802.1x
Portal authentication and RADIUS authentication
OSPF, RIPv2, BGPv4 pain text and MD5 authentication
Secure network management via SNMPv3 and SSHv2
Unknown unicast/multicast, Broadcast packet suppression
Active/standby data backup
System management Command line configuration via Console/AUX Modem/Telnet/SSH2.0
File uploading and downloading via FTP, TFTP, Xmodem, and SFTP
SNMP V1/V2c/V3
RMON and groups 1, 2, 3 and 9
NTP clocks
NQA(Network Quality Analyzer)
Fault alarm and automatic fault recovery
System logs
Temperature Operating temperature: 0°C to 40°C (32°F to 104°F)
Storage temperature: -40°C to 70°C (-40°F to 158°F)
Humidity 5% to 95% (non-condensing)
Environmental protection WEEE, RoHS
Safety CE, U/cUL, FCC-PART15, VCCI
Maximum power consumption 1380W 3300W
Weight (full configuration) ≤40 kg ≤80 kg
Dimensions (H x W x D) 88.1 x 440 x 720mm 220 x 440 x 720mm

 

Tingnan ang karagdagang mga detalye tungkol sa IMPACT ARROW SOLUTION SDN BHD
IMPACT ARROW SOLUTION SDN BHD
IMPACT ARROW SOLUTION SDN BHD Dahua Supplier Selangor, Hikvision Supply Kuala Lumpur (KL), CCTV System Installer Malaysia ~ IMPACT ARROW SOLUTION SDN BHD