Heating elements on support tubes radiating freely into the furnace chamber provide for particularly short heating times for these muffle furnaces. Thanks to their robust lightweight refractory brick insulation, they can reach a maximum working temperature of 1300 °C. These muffle furnaces thus represent an interesting alternative to the familiar L(T) ../12 models, when you need a higher application temperature.
Model | Tmax | Inner dimensions in mm | Volume | Outer dimensions2 in mm | Temperature uniformity of +/− 5K in the empty workspace5 | Connected load | Electrical | Weight | Heating time | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
in °C1 | w | d | h | in l | W | D | H3 | w | d | h | in kW | connection* | in kg | in min4 | |
L, LT 5/13 | 1300 | 200 | 170 | 130 | 5 | 490 | 450 | 580+320 | 170 | 100 | 80 | 2.4 | 1-phase | 42 | 60 |
L, LT 9/13 | 1300 | 230 | 240 | 170 | 9 | 530 | 525 | 630+350 | 180 | 170 | 120 | 3.0 | 1-phase | 60 | 60 |
L, LT 15/13 | 1300 | 230 | 340 | 170 | 15 | 530 | 625 | 630+350 | 180 | 270 | 120 | 3.2 | 1-phase | 70 | 70 |
1Recommended working temperature for processes with longer dwell times is 1200 °C*Please see page 75 for more information about supply voltage 2External dimensions vary when furnace is equipped with additional equipment. Dimensions on request. 3Including opened lift door (LT models) 4Heating time of the empty and closed furnace up to Tmax −100 K (connected to 230 V 1/N/PE) 5Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C |