The combi chamber furnaces N 100 DB - N 1500/14 DB are specially developed for debinding and sintering in one process. The furnaces have a fresh air supply providing for dilution of the exhaust gases produced during debinding, for safe prevention of an inflammable atmosphere in the furnace chamber. The standard version of the furnaces is equipped with the debinding package DB100. This debinding package provides for an injection of fresh air for atmosphere dilution which means that the furnace works under overpressure during debinding.
As a professional solution for production furnaces, we recommend the debinding package DB200. The furnace then has a warm fresh-air injection with variable speed through distribution tubes in the furnace chamber. The exhaust fan operates also with a variable fan speed. The PLC automatically regulates a negative pressure inside the furnace chamber.
Model | Tmax | Inner dimensions in mm | Volume | Outer dimensions1 in mm | Heating power for single-zone heating control | Electrical | Weight | ||||
---|---|---|---|---|---|---|---|---|---|---|---|
°C | w | d | h | in l | W | D | H | kW2 | connection | in kg | |
N 100 DB50 | 1280 | 400 | 530 | 460 | 90 | 1100 | 1150 | 1850 | 11 | 3-phase | 350 |
N 200 DB.. | 1280 | 400 | 530 | 720 | 140 | 850 | 1350 | 2220 | 15 | 3-phase | 500 |
N 300 DB.. | 1280 | 450 | 700 | 780 | 230 | 900 | 1600 | 2280 | 20 | 3-phase | 800 |
N 450 DB.. | 1280 | 550 | 760 | 1000 | 350 | 1390 | 1570 | 2520 | 40 | 3-phase | 1400 |
N 650 DB.. | 1280 | 660 | 850 | 1100 | 610 | 1250 | 1680 | 2720 | 62 | 3-phase | 1600 |
N 1000 DB.. | 1280 | 740 | 1000 | 1250 | 940 | 1800 | 1800 | 2800 | 57 | 3-phase | 2700 |
N 1500 DB.. | 1280 | 840 | 1200 | 1400 | 1400 | 1660 | 2300 | 2950 | 75 | 3-phase | 3300 |
N 100/H DB50 | 1340 | 400 | 530 | 460 | 90 | 1100 | 1150 | 1850 | 15 | 3-phase | 350 |
N 200/H DB.. | 1340 | 400 | 530 | 720 | 140 | 850 | 1350 | 2220 | 22 | 3-phase | 500 |
N 300/H DB.. | 1340 | 450 | 700 | 780 | 230 | 900 | 1600 | 2280 | 30 | 3-phase | 800 |
N 450/H DB.. | 1340 | 550 | 760 | 1000 | 350 | 1390 | 1570 | 2520 | 40 | 3-phase | 1400 |
N 650/H DB.. | 1340 | 660 | 850 | 1100 | 610 | 1250 | 1680 | 2720 | 62 | 3-phase | 1600 |
N 1000/H DB.. | 1340 | 740 | 1000 | 1250 | 940 | 1800 | 1800 | 2800 | 75 | 3-phase | 2700 |
N 1500/H DB.. | 1340 | 840 | 1200 | 1400 | 1400 | 1660 | 2300 | 2950 | 110 | 3-phase | 3300 |
N 100/14 DB50 | 1400 | 400 | 530 | 460 | 90 | 1100 | 1150 | 1850 | 15 | 3-phase | 350 |
N 200/14 DB.. | 1400 | 400 | 530 | 720 | 140 | 850 | 1350 | 2220 | 22 | 3-phase | 500 |
N 300/14 DB.. | 1400 | 450 | 700 | 780 | 230 | 900 | 1600 | 2280 | 30 | 3-phase | 800 |
N 450/14 DB.. | 1400 | 550 | 760 | 1000 | 350 | 1390 | 1570 | 2520 | 40 | 3-phase | 1400 |
N 650/14 DB.. | 1400 | 660 | 850 | 1100 | 610 | 1250 | 1680 | 2720 | 62 | 3-phase | 1600 |
N 1000/14 DB.. | 1400 | 740 | 1000 | 1250 | 940 | 1800 | 1800 | 2800 | 75 | 3-phase | 2700 |
N 1500/14 DB.. | 1400 | 840 | 1200 | 1400 | 1400 | 1660 | 2300 | 2950 | 110 | 3-phase | 3300 |
1Outer dimensions vary depending on the scope of supply. Dimensions on request. 2Depending on furnace design connected load might be higher |