Deskripsyon
Vacuum Science Simplified
We know vacuum applications can get complicated, and the FYRA was created to deliver scientific measurement and vacuum control simply. The FYRA can be easily integrated into almost any system in the market with its ability to drive multiple types of sensors (piezo, thermal, active, passive, and capacitance manometers) and its high configurability.
The DigiVac FYRA Vacuum Controller Distillation Bundle specifically was created to include diagnostic capabilities. It has 2 sensors – one connected to the system and one connected to the roughing pump. By comparing the readings between the two sensors, you can detect whether everything is running as it should or if there are any potential leaks or problems.
Package Includes:
-
FYRA Vacuum Controller
-
(2) Agilent 536 KF25 Thermocouple Sensors and driver cards
-
(1) Bellows-type Throttle Valve and driver card
-
Options: WiFi
-
Optional: Installation Kit (Aluminum Wing Clamps + Stainless Steel/Viton Centering Rings). Please fill out the product inquiry below to add this option.
Bellows KF25 Valve: works by throttling the pressure between the vacuum pump and the process to control the vacuum level or to isolate the vacuum pump | Enables vacuum pressure control a solenoid valve for throttling pump suction.
-
Control Range: 10 millitorr to 6 Torr
-
Measurement Range: 1 millitorr to 760 Torr
-
Range with accuracy: 10 millitorr to 6 Torr
-
Benefits of Bellows Throttle Control: With the KF25 1″ orifice you get better and faster throughput | ideal for processing high volumes | Extends life of pump by enabling pump to run closer to it’s base pressure
Optional WiFi Connection
View pressure in real time through vacuumnetwork.org, and log data through the USB interface.
Choose Digivac for your
Distillation needs.
Example of a FYRA Application
-
Distillation Vacuum Controller Applications— R&D: Vacuum Ovens, Vacuum Furnaces, Vacuum Bagging or Composites
-
Botanical Processing: Rotary Evaporation, Short Path Distillation (1 Head Kit), Extractions
-
Use Case Example— To maintain specific pressure levels in a vacuum oven at about 2 Torr to avoid removing target terpenes and only removing water
Alternative Solutions
This set-up can be used to monitor both sides of a 2 Head Distillation set-up and a
Bullseye Precision Gauge can be used to monitor the pressure at the
roughing pump. This version comes with a Bellow-type throttle valve which works by throttling the pressure between the vacuum pump and the process to control the vacuum level, or to isolate the vacuum pump. It enables vacuum pressure control using a solenoid valve for throttling pump suction. Throttle Vacuum Control from 10 mT to 6 Torr with a high flow bellows valve helps you monitor and control molecular flow in your distillation application.
Short Path Distillation Summary
Short path distillation is a process that occurs after extraction. It is a type of botanical processing, generally utilized for the molecular separation of botanical fluids to achieve high potency. “Short path” refers to the short distance the oil travels, relative to the notoriously large industrial distillation units most people know. Wiped film distillation is a type of short path distillation.
Read our Distillation Application Note
Vacuum for Short Path Distillation
One of the primary purposes of using vacuum in distillations is to lower the temperature required to achieve a boiling point. The target product in a distillation could either be the remaining product, the distilled product, or a purified product. The vacuum associated with a distillation depends on the product to be distilled. Volatile substances are likely to undergo vacuum distillations above 1 Torr. Composite distillations typically require precise pressure control in the region above 1 Torr.
Technical Specifications
Units |
Torr, mbar, kPa, microns, millitorr, mmHg, Hectopascal |
Control Range |
1E-4 – 1000 Torr |
Dimensions |
6.5″x6.5″x2.5″ |
Telemetry Options |
USB, WiFi, 0-10 volts DC, Analog out, 0-10 volts DC Analog in |
Sensor Support |
MKS Convectron: 275071 (1/8″ NPT), 275203 (KF16); DigiVac: SEN-VGT500, SEN-775i, Quantum (SEN-DPP, SEN-DCP, SEN-DPCP); Pfeiffer: PKR251, IKR251; Agilent: FRG700, PCG-750, PCG700, 531, 536, 531 equivalent, or PVG 500; Setra: 730 capacitance manometers; Inficon: PSG500, PSG550, Porter, SKY, Stripe, MAG, MPG & MPG400 |
Valve Support |
Dinamo, VacStable (Bleed), Solenoid-type Bellows and Plunger, 24V valves that are less than 24 Watts |
Compatible Sensors:
Sensors supported include: |
|
Inficon |
MPG400/401
PSG5xx ATM to Medium Vacuum Gauge
Gemini MAG500 Cold Cathode
Gemini MPG500 Cold Cathode Pirani
PCG550
Porter
SKY
Stripe
MAG |
MKS |
AA01, 722B, 730B
Convection: 27571 (1/8″ NPT), 275203 (KF16) |
KJLC |
KJLC Pirani
KJLC Cold Cathode
KJLC Cold Cahtode Pirani
AGC 0.1 T CM
AGC 0.5 T CM
AGC 1 T CM
AGC 5 T CM
AGC 10 T CM
AGC 20 T CM
AGC 50 T CM
AGC 100 T CM
AGC 1000 T CM |
Agilent |
PVG-500
PVG-550
IKR251
FRG-700
FRG-720
PCG-750
PCG-700
536
531
CDG500 1 T CM
CDG500 10 T CM
CDG500 100 T CM
CDG500 1000 T CM |
Edwards |
ASG2, APG200-XM, WRG200 |
DigiVac |
SEN-VGT500
SEN-775i
Quantum (SEN-DPP, SEN-DCP, SEN-DPCP) |
Pfieffer |
PKR251
IKR251 |
Leybold |
Ceravac: 1, 10, 100, 1000T CM
Thermovac: TTR 91, TTR 96, TTR 97, TTR 101, TTR 200N |
Sentra |
730 capacitance manometers |
Tingnan ang karagdagang mga detalye tungkol sa Hexo Industries (M) Sdn Bhd