F701-P is a weighing indicator with convenient functions and operability for weighing such as a high-precision amplifier, fast-sampling, High-Low limit comparison function, weighing function and accumulation functions.
AnalogSettingExternal signalInterfaceDisplayGeneral specificationAttachment
Analog | |
Excitation voltage | DC5V±5% Output currentwithin 90mA Ratio metric type (Up to six 350Ω load cells can be connected in parallel.) |
---|---|
Signal input range | 0.53.0mV/V |
Zero adjustment range |
Automatic adjustment by digital operation 0.22.0mV/V |
Span adjustment range |
Automatic adjustment by digital operation |
Minimum input sensitivity | 0.15μV/count |
Accuracy |
|
A/D converter |
Conversion rate…300times/sec. Conversion resolution…24bitbinary |
Minimum indication resolution | 1/10000 |
Setting | |
Setting method |
Settings are made by operating the membrane keys. Also, settings can be made from a host computer through the RS-485 interface. |
---|---|
Memory of set value | F-RAM (nonvolatile RAM) |
Protect of set value | Software LOCK can be set to parameter such as ''Set value'' and ''Calibration''. |
Setting item |
Upper limitLower limitNear zeroSet point 1Set point 2CompensationOverUnderFinalComparison inhibit timeJudging timeComplete output timeWeighing function 1Weighing function 2Tare settingTare displayDigital low pass filterMoving average filterMotion detectionZero tracking (Period)Zero tracking (Range)Total comparison selectionTotal limit (high 4 digit) Total limit (under 5 digit) Count limitKey invalidLOCKInput selectionOutput selectionPasswordBalance weight valueCapacityMin. scale divisionDZ regulation valueDisplay selectionGravitational accelerationZero calibrationSpan calibrationRS-485 I/F settingCommunication typeRS-485 IDTransmission delay time |
External signal You can specify whether PNP (Source) type or NPN (Sink) type when order the F701-P. | |
Output signals 4 points |
Select from COMPL.SP1SP2SP3HIGOLOSTABWEIGHT ERRORTOTAL FINAL At signal ON, output transistor ON. External voltage must be prepared separately by customer. |
---|---|
Input signals 4 points |
Select from G/ND/Z ONTARE ONTARE OFFACCUMULATION CLEARHOLD/JUDGE Contact (relay, switch etc.) or non-contact (transistor, open collector etc.) can be connected. External voltage must be prepared separately by customer. |
Interface | |
RS-485 communication interface Select from Modbus-RTU and original format |
Display | |
Display |
18.5mm in character height, Numerical display on LCD(7 digit) Sub display7.3mm in character height (14 digit) |
---|---|
Indicated value | 5 digitsign: negative display at the highest digit |
Accumulation value | 9 digitThis can be changed to ''Accumulation count (4 digit)'' and ''Final(5 digit)''. |
Display frequency | Select from 1, 2, 5, 10, 20 times/sec.(The system speed is 300 times/sec.) |
Capacity | 5 digit |
Min. scale division | Setting allowable in the range of 150. |
Decimal point | Select from 0, 0.0, 0.00, 0.000 |
Over display |
LOADA/D converter input over, OFL1Net Over, OFL2Capacity + 9 scale division, OFL3Gross Over |
Center zero | A true zero point or the center of each value is displayed. |
Status display |
COMPL.SP3SP2SP1HIGOLOZT NZHOLDZALMSTABTARENETGROSSCZ |
General specification | |
Power supply voltage | AC100240V(1015) free power source 50/60Hz |
---|---|
Power consumption | Approx. 5W |
Inrush current |
1.5A, 0.7mSec:AC100V average load condition cold start at room temperature 2.5A, 0.7mSec:AC200V average load condition cold start at room temperature |
Operating conditions |
Temperature…Operation 10桫40桡Storage 20桫85 Humidity…85%RH or less (non-condensing) |
External dimensions | 192(W)×96(H)×102(D) mm (Projections excluded) |
Panel cutout dimensions |
186 +2 -0(W)×92 +1 -0(H)mm Installation panel thickness: 2.03.2mm |
Weight | Approx. 1.3kg |
Attachment | |
AC input cord (Nominal rating 125V) 3m | 1 |
---|---|
Jumper line | 2 |
Terminator | 1 |
Operation manual | 1 |
Rubber packing | 1 |
Product | Description |
CN80 |
Loadcell input connector terminal (7P) |
---|