HOW TO ORDER
FPG | -02 | -75 | |
SERIES NUMBER FPG FPE |
VALVE SIZE 02 |
PRESSURE ADDITION. RANGE (kgf/cm²) 0-75 0-175 0-310 |
QMAX:l/min 40 |
MODEL | FLOW (l/min) | PRESSURE ADJUSTING RANGE (kgf/cm²) | RATED CURRENT (Ma) | COIL CURRENT POWER W | COIL RESISTANCE (Ω) | HYSTERESIS | REPEATABILITY | PRESPONSE TIME (ms) 100% | USED AMPLIFIER | WEIGHT kg | |
ON | OFF | ||||||||||
FPG-02-75 | 40 | 0-75 | 0.8 MAX. | 62 MAX. | 22 | 4% | 10% | 200 | 250 | FPE-081 | 2.3 |
FPG-02-175 | 0-175 | ||||||||||
FPG-02-310 | 0-310 |