Pressure:
from 0,6 to 2,3 bar
Pumping speed:
100÷360 m3/h
The compression chamber is free of lubricating or sealing fluids.
The gears are oil bath type and the same oil is used to lubricate the bearings. The oil sump is separated from the compression chamber by labyrinth seals.
Cooling is guaranteed by a fan.
The electric motor is flanged and connected to the lower shaft with a coupling.
|
|
|
DRY C 100 P |
DRY C 300 P |
||||||||
Pumping speed |
m³/h |
50Hz |
100 |
300 |
||||||||
60Hz |
120 |
360 |
||||||||||
Ultimate pressure with gas ballast (g) |
bar |
50Hz |
0,6 |
1 |
1,5 |
2,3 |
0,5 |
0,75 |
1,2 |
2,1 |
||
60Hz |
0,5 |
0,8 |
1,2 |
2,1 |
0,45 |
0,65 |
1,1 |
1,8 |
||||
Motor power |
kW |
50Hz |
2,2 |
3 |
4 |
5,5 |
5,5 |
7,5 |
11 |
15 |
||
60Hz |
2,7 |
3,6 |
4,8 |
6,6 |
6,6 |
9 |
13,2 |
18 |
||||
Motor speed |
rpm |
50Hz |
3000 |
3000 |
||||||||
60Hz |
3600 |
3600 |
||||||||||
Lubricant charge |
l |
|
0,5 |
2 |
||||||||
Sound pressure level |
dB(A) |
50Hz |
76 |
80 |
||||||||
60Hz |
78 |
84 |
||||||||||
Dimensions |
L |
mm |
|
723 |
744 |
771 |
771 |
946 |
84 |
1174 |
1194 |
|
B x H |
|
424x402 |
447x540 |
|||||||||
Weight |
kg |
50Hz |
105 |
112 |
115 |
131 |
225 |
229 |
310 |
321 |
||
60Hz |
||||||||||||
Connections* |
Inlet |
|
1” ½ Gas |
2” Gas |
||||||||
Outlet |
|
1” ½ Gas |
2” Gas |
* Other types of connection available upon request