详情
Item Data
Inserts MatchingD6B Hoods&Housings
APPROVAL UL.CSA.VDE.CE.CQC
Test standard DIN EN61 984 / UL1977
Poles 16P+PE
The need for additional or dering crimp contacts No
EN61984 Test data /
Rated voltage [V] 250
Rated current [A] 16
pollution degree 3
Rated impulse voltage [KV] 4
Insulation resistance ≥1010Ω
UL/CSARated current [V] 600
Material Polycarbonate
Inflammability class(UL94) V-0
Ambient temperature [℃] -40~+125
Mechanical working life(mating cycles) ≥500
Contacts
Material Copper alloy
Surface Hard-silver plated
Contact resistance ≤1mΩ
Terminal Screw terminal
Rated torque [N·m] 0.5
Rated connection capacity(solid/stranded) 1.0-2.5mm² (AWG18-14)
Screw M3, Steel,Ni plated
Wire connecting
Recommended stripping length 7.5mm;
For solid wire, stripping wire to the appointed length, then tightening with rated torque.
For stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque.