KSD9700 K60 60掳C Normally Open Metal shell Temperature Control Switch Thermostats (5pcs)

KSD9700 K60 60掳C Normally Open Metal shell Temperature Control Switch Thermostats (5pcs)

Category: Available (Qty:9999999)
For more information, visit our official website at utsource.us

Description

BUY KSD9700 K60 60°C Normally Open Metal shell Temperature Control Switch Thermostats (5pcs) https://www.utsource.net/itm/p/12604919.html

Parameter Description
Model KSD9700 K60
Type Temperature Control Switch, Thermostat
Switching Type Normally Open (NO)
Operating Temperature 60°C (140°F)
Housing Material Metal Shell
Contact Form Single Pole, Single Throw (SPST)
Rated Voltage AC 250V, DC 30V
Rated Current 10A
Contact Resistance ≤ 50mΩ
Dielectric Strength 1500VAC for 1 minute
Insulation Resistance ≥ 100MΩ at 500VDC
Operating Humidity 95% RH (non-condensing)
Life Expectancy 10,000 cycles
Mounting Method Screw Terminal
Dimensions 18mm (Diameter) x 25mm (Length)
Weight 10g
Package Quantity 5 pcs

Instructions for Use

  1. Preparation:

    • Ensure the switch is suitable for the application by checking the rated voltage, current, and temperature.
    • Prepare the wiring according to the electrical requirements of the system.
  2. Installation:

    • Mount the thermostat in a location where it will accurately sense the temperature of the environment or device being controlled.
    • Secure the thermostat using the provided mounting method (screw terminal).
    • Connect the wires to the screw terminals, ensuring a secure and tight connection to prevent arcing or poor contact.
  3. Operation:

    • The switch will open (disconnect) when the temperature reaches 60°C.
    • The switch will remain open until the temperature drops below the reset point, which is typically slightly lower than the operating temperature due to hysteresis.
    • Ensure that the system is designed to handle the open circuit condition when the switch activates.
  4. Maintenance:

    • Regularly inspect the connections and mounting to ensure they are secure and free from corrosion.
    • Test the operation of the switch periodically to ensure it is functioning correctly.
    • Replace the switch if it shows signs of wear, damage, or if it fails to operate as expected.
  5. Safety Precautions:

    • Do not exceed the rated voltage and current to avoid damage or fire hazards.
    • Ensure proper ventilation around the thermostat to prevent overheating.
    • Follow all local electrical codes and safety standards during installation and use.
    • Use appropriate personal protective equipment (PPE) when handling electrical components.