KSD-01F D60 60掳C Normally Close Temperature Control Switch Thermostats

KSD-01F D60 60掳C Normally Close Temperature Control Switch Thermostats

Category: Available (Qty:9999999)
For more information, visit our official website at utsource.us

Description

BUY KSD-01F D60 60掳C Normally Close Temperature Control Switch Thermostats https://www.utsource.net/itm/p/12604918.html

Parameter Description
Model KSD-01F D60
Type Normally Closed (NC) Temperature Control Switch
Temperature Rating 60掳C
Contact Form SPST-NC (Single Pole Single Throw - Normally Closed)
Operating Temperature 60掳C 卤 5掳C
Differential Temperature 5掳C - 15掳C
Electrical Rating 125VAC / 16A, 250VAC / 10A
Insulation Resistance > 100M惟 at 500VDC
Dielectric Strength 2000VAC for 1 minute
Contact Resistance < 50m惟
Life Expectancy 10,000 cycles (min)
Operating Humidity 95% RH (max)
Mounting Position Any position
Dimensions 14mm (Diameter) x 19.5mm (Height)
Weight 3g
Material Housing: Phenolic resin, Contacts: Silver alloy
Certifications UL, CSA, VDE, CQC

Instructions for Use

  1. Installation:

    • Ensure the thermostat is installed in a location where it can accurately sense the temperature of the environment or device it is controlling.
    • Mount the thermostat securely to avoid movement or vibration that could affect its performance.
  2. Wiring:

    • Connect the normally closed (NC) contacts to the load and power source.
    • Ensure all connections are tight and secure to prevent arcing or overheating.
  3. Operation:

    • The switch will remain closed until the temperature reaches 60掳C.
    • At 60掳C, the switch will open, breaking the circuit.
    • The switch will reset when the temperature drops below the differential range (5掳C - 15掳C below 60掳C).
  4. Maintenance:

    • Regularly inspect the thermostat for signs of wear or damage.
    • Clean the thermostat with a dry cloth to remove dust and debris.
    • Do not use solvents or abrasive materials as they may damage the housing or contacts.
  5. Storage:

    • Store the thermostat in a cool, dry place away from direct sunlight and extreme temperatures.
    • Avoid storing the thermostat in environments with high humidity or corrosive gases.
  6. Safety:

    • Always disconnect the power before installing or servicing the thermostat.
    • Do not exceed the electrical ratings specified for the thermostat.
    • Replace the thermostat if it shows signs of malfunction or damage.
(For reference only)

More detail about Utsource Holding Company Limited
Utsource Holding Company Limited
Utsource Holding Company Limited Electronic Component Wholesaler, IC Chip Distributor, IGBT Module Supplier in California, USA | Utsource Holding Company Limited