Description
BUY KSD301 B70 70掳C NORMALLY CLOSE JUMP TYPE TEMPERATURE CONTROL SWITCH THERMOSTATS (5PCS) https://www.utsource.net/itm/p/12604306.html
Parameter |
Value |
Model Number |
KSD301 B70 |
Type |
Temperature Control Switch Thermostat |
Switching Type |
Normally Closed (NC) |
Operating Temperature |
70掳C |
Reset Type |
Jump Type |
Contact Form |
SPST-1C (Single Pole Single Throw - 1 Closed) |
Maximum Current |
16A |
Maximum Voltage |
250VAC / 125VDC |
Housing Material |
Phenolic Resin |
Terminal Type |
Quick Connect (QD) |
Operating Humidity |
95% RH at 40掳C |
Insulation Resistance |
>100M惟 at 500VDC |
Dielectric Strength |
1800VAC for 1 minute |
Operating Life |
10,000 cycles |
Storage Temperature |
-40掳C to +85掳C |
Mounting Method |
Snap-in or Screw Mount |
Dimensions |
20mm x 16mm x 14mm (L x W x H) |
Weight |
10g |
Package Quantity |
5 PCS |
Instructions for Use:
Installation:
- Ensure the thermostat is installed in a location where it will not be obstructed by other components.
- Use the snap-in or screw mount method to secure the thermostat in place.
- Connect the wires to the quick connect terminals.
Wiring:
- Connect the load to the normally closed (NC) terminal.
- Connect the power source to the common (COM) terminal.
- Ensure all connections are tight and secure to prevent loose connections.
Operation:
- The switch will remain closed until the temperature reaches 70掳C.
- When the temperature exceeds 70掳C, the switch will open, breaking the circuit.
- Once the temperature drops below the reset point, the switch will automatically jump back to the closed position, restoring the circuit.
Maintenance:
- Regularly inspect the thermostat for any signs of damage or wear.
- Clean the thermostat with a dry cloth to remove dust and debris.
- Replace the thermostat if it shows signs of malfunction or if it has reached its operating life limit.
Precautions:
- Do not exceed the maximum current and voltage ratings.
- Avoid exposing the thermostat to temperatures outside its operating range.
- Ensure proper ventilation around the thermostat to prevent overheating.
- Do not modify the thermostat as this can affect its performance and safety.