Description
BUY MDF11N65B https://www.utsource.net/itm/p/12613928.html
Parameter |
Symbol |
Min |
Typical |
Max |
Unit |
Conditions |
Drain-Source Voltage |
VDS |
- |
650 |
- |
V |
|
Gate-Source Voltage |
VGS |
-20 |
- |
20 |
V |
|
Continuous Drain Current |
ID |
- |
11 |
- |
A |
TC = 25掳C |
Pulse Drain Current |
IDpeak |
- |
33 |
- |
A |
tp = 10 渭s, IGT = 4 A |
Total Power Dissipation |
PTOT |
- |
190 |
- |
W |
TC = 25掳C |
Junction Temperature |
TJ |
- |
- |
150 |
掳C |
|
Storage Temperature Range |
TSTG |
-55 |
- |
150 |
掳C |
|
Thermal Resistance, Junction to Case |
R胃JC |
- |
0.8 |
- |
掳C/W |
|
Input Capacitance |
Ciss |
- |
1700 |
- |
pF |
VDS = 400 V, f = 1 MHz |
Output Capacitance |
Coss |
- |
110 |
- |
pF |
VDS = 400 V, f = 1 MHz |
Reverse Transfer Capacitance |
Crss |
- |
50 |
- |
pF |
VDS = 400 V, f = 1 MHz |
Turn-On Delay Time |
td(on) |
- |
45 |
- |
ns |
VGS = 15 V, ID = 11 A |
Rise Time |
tr |
- |
45 |
- |
ns |
VGS = 15 V, ID = 11 A |
Turn-Off Delay Time |
td(off) |
- |
45 |
- |
ns |
VGS = -15 V, ID = 11 A |
Fall Time |
tf |
- |
45 |
- |
ns |
VGS = -15 V, ID = 11 A |
Instructions for Use:
Handling Precautions:
- Handle the MDF11N65B with care to avoid damage to the leads and body.
- Use ESD (Electrostatic Discharge) protection when handling to prevent damage from static electricity.
Mounting:
- Ensure proper heat sinking to manage the thermal resistance and maintain the junction temperature within safe limits.
- Follow recommended PCB layout guidelines to minimize parasitic inductances and ensure reliable operation.
Biasing:
- Apply the gate-source voltage (VGS) within the specified range to avoid damage.
- Use a gate resistor to control the switching speed and reduce EMI (Electromagnetic Interference).
Operation:
- Operate the device within the specified drain-source voltage (VDS) and continuous drain current (ID) ratings.
- Monitor the junction temperature (TJ) to ensure it does not exceed the maximum rating.
Storage:
- Store the device in a dry, cool environment within the specified storage temperature range (TSTG).
Testing:
- Use appropriate test equipment and methods to verify the performance parameters.
- Ensure that all testing is performed under controlled conditions to avoid damage to the device.
Safety:
- Follow all relevant safety guidelines and regulations when using the MDF11N65B.
- Use protective equipment as necessary to prevent injury.
(For reference only)