Description
BUY BTB12-600CW https://www.utsource.net/itm/p/11743102.html
Parameter |
Symbol |
Value |
Unit |
Maximum Repetitive Peak Off-State Voltage |
VDRM |
600 |
V |
Maximum Repetitive Peak On-State Voltage |
VRRM |
600 |
V |
Maximum RMS On-State Current (100% duty cycle) |
IT(RMS) |
12 |
A |
Maximum Non-Repetitive Peak On-State Current (8.3 ms, sin 50 Hz) |
IWM |
72 |
A |
Maximum Gate Trigger Current (TJ = 25掳C) |
IG(T) |
100 |
mA |
Maximum Gate Trigger Voltage (TJ = 25掳C) |
VG(T) |
2.0 |
V |
Maximum Gate Trigger Current (TJ = 100掳C) |
IG(T) |
200 |
mA |
Maximum Gate Trigger Voltage (TJ = 100掳C) |
VG(T) |
2.5 |
V |
Holding Current |
IH |
10 |
mA |
Junction Temperature |
TJ |
-40 to +125 |
掳C |
Storage Temperature |
TSTG |
-40 to +125 |
掳C |
Instructions for Use:
Mounting and Handling:
- Ensure that the device is mounted on a suitable heatsink to maintain junction temperature within specified limits.
- Handle the device with care to avoid mechanical damage.
Electrical Connections:
- Connect the anode and cathode terminals correctly to avoid reverse polarity which can lead to device failure.
- The gate terminal should be connected to the control circuit with appropriate current limiting resistors to prevent excessive gate current.
Thermal Management:
- Ensure adequate cooling to keep the junction temperature within the specified range. Excessive temperature can reduce the life of the device and cause immediate failure.
- Use thermal paste between the device and heatsink to improve heat transfer.
Gate Triggering:
- Apply a gate trigger pulse with sufficient amplitude and duration to ensure reliable turn-on. The recommended gate trigger current is at least 100 mA for TJ = 25掳C and 200 mA for TJ = 100掳C.
- Ensure the gate trigger voltage is within the specified range to avoid overvoltage conditions.
Operating Conditions:
- Do not exceed the maximum ratings for voltage, current, and temperature.
- Avoid operating the device in conditions where it may experience excessive thermal cycling or mechanical stress.
Storage:
- Store the device in a dry, cool place away from direct sunlight and sources of heat.
- Follow ESD (Electrostatic Discharge) precautions to prevent damage to the device.
Testing:
- Before installation, test the device using a suitable tester to ensure it meets the specified parameters.
- Regularly inspect the device and connections for signs of wear or damage.
By following these guidelines, you can ensure reliable and safe operation of the BTB12-600CW triac.
(For reference only)
More detail about Utsource Holding Company Limited