Description
BUY MUR260RLG https://www.utsource.net/itm/p/11711214.html
Parameter |
Symbol |
Min |
Typ |
Max |
Unit |
Notes |
Forward Voltage |
VF |
- |
1.1 |
1.3 |
V @ IF = 10 A |
|
Reverse Blocking Voltage |
VR(RM) |
200 |
- |
- |
V |
|
Average Rectified Current |
IF(AV) |
- |
- |
20 |
A |
TA = 25掳C |
Peak Surge Current |
ISM |
- |
- |
200 |
A |
t = 8.3 ms, sine half wave |
Junction Temperature |
TJ |
- |
- |
150 |
掳C |
|
Storage Temperature |
TSTG |
-55 |
- |
150 |
掳C |
|
Thermal Resistance |
R胃JC |
- |
1.6 |
- |
掳C/W |
|
Instructions for Use:
Mounting:
- Ensure that the device is mounted on a heatsink if operating at high current or in high ambient temperatures to maintain junction temperature within limits.
- Use appropriate thermal interface materials (TIMs) to enhance heat dissipation.
Electrical Connections:
- Connect the anode and cathode terminals correctly to avoid reverse bias conditions that could exceed the reverse blocking voltage.
- Ensure that the peak surge current does not exceed 200 A to prevent damage to the diode.
Operating Conditions:
- The average rectified current should not exceed 20 A at an ambient temperature of 25掳C.
- Monitor the junction temperature to ensure it does not exceed 150掳C to prevent thermal runaway.
Storage:
- Store the device in a dry environment with temperatures between -55掳C and 150掳C to maintain reliability.
Handling:
- Handle the device with care to avoid mechanical stress or damage to the leads.
- Follow ESD (Electrostatic Discharge) precautions to prevent damage from static electricity.
Testing:
- Use appropriate test equipment and methods to verify the parameters before integrating the diode into the circuit.
- Perform tests under controlled conditions to ensure accurate results.
(For reference only)
More detail about Utsource Holding Company Limited