Description
BUY GS-R51212S https://www.utsource.net/itm/p/8852989.html
Parameter |
Symbol |
Conditions |
Min |
Typ |
Max |
Unit |
Supply Voltage |
VDD |
Operating condition |
2.7 |
- |
5.5 |
V |
Output Current |
IOUT |
Continuous |
- |
1.2 |
1.5 |
A |
Peak Current |
IPK |
Pulse width = 10ms |
- |
2.5 |
- |
A |
Quiescent Current |
IQ |
VOUT = 3.3V |
- |
40 |
- |
μA |
Dropout Voltage |
VDROPOUT |
IOUT = 500mA |
- |
0.3 |
- |
V |
Load Regulation |
ΔVO/ΔIL |
IOUT: 0mA to 500mA |
- |
0.5 |
- |
% |
Line Regulation |
ΔVO/ΔVIN |
VIN: 2.7V to 5.5V |
- |
0.1 |
- |
% |
Ripple Rejection |
RR |
f = 120Hz |
- |
60 |
- |
dB |
Operating Junction Temp |
TJ |
|
-40 |
- |
125 |
°C |
Storage Temperature |
TSTG |
|
-40 |
- |
150 |
°C |
Instructions for Use:
- Power Supply Connection: Ensure the supply voltage (VDD) is within the specified range of 2.7V to 5.5V.
- Output Configuration: The device can provide a continuous output current up to 1.5A. For peak currents, ensure not to exceed 2.5A for pulse widths of 10ms.
- Thermal Management: Keep the operating junction temperature between -40°C and 125°C. Consider heat dissipation solutions if necessary.
- Load Regulation: The load regulation is typically 0.5%, meaning the output voltage changes by 0.5% when the load current varies from 0mA to 500mA.
- Line Regulation: Typically at 0.1%, indicating minimal change in output voltage with varying input voltage.
- Ripple Rejection: At 120Hz, the device offers 60dB ripple rejection, ensuring stable output under noisy conditions.
- Storage Conditions: Store the device in environments where temperatures do not exceed -40°C to 150°C.
- Quiescent Current: With an output voltage set at 3.3V, the quiescent current is typically 40μA, which helps in minimizing power consumption.
- Dropout Voltage: Operates efficiently with a typical dropout voltage of 0.3V at an output current of 500mA.
Ensure all connections are secure and within specified limits to avoid damage to the device.
(For reference only)
More detail about Utsource Holding Company Limited