Description
BUY YAC516-E https://www.utsource.net/itm/p/12607423.html
Parameter |
Description |
Value |
Unit |
Part Number |
Product identifier |
YAC516-E |
- |
Type |
Device type |
AC/DC Converter |
- |
Input Voltage |
Range of input voltage it can handle |
85 to 264 |
VAC |
Output Voltage |
Stable output voltage provided |
5 |
VDC |
Output Current |
Maximum current it can provide |
3 |
A |
Efficiency |
Efficiency rating |
Up to 87% |
% |
Operating Temp. |
Temperature range for operation |
-40 to +85 |
°C |
Protection |
Types of protection features |
Overload, Short-circuit |
- |
Mounting |
Method of installation |
DIN Rail |
- |
Certifications |
Safety and compliance standards met |
CE, UL |
- |
Instructions:
- Installation: Install the YAC516-E on a standard DIN rail in a well-ventilated area to ensure proper heat dissipation.
- Input Connection: Connect the input terminals to an AC power source within the specified voltage range (85 to 264 VAC).
- Output Connection: Connect your DC load to the output terminals ensuring the total current draw does not exceed 3A.
- Protection Settings: The device includes built-in overload and short-circuit protection which automatically resets once the fault condition is cleared.
- Operating Environment: Ensure the ambient temperature remains between -40°C and +85°C for optimal performance.
- Safety Compliance: Verify that the installation complies with local electrical codes and regulations. The YAC516-E meets CE and UL safety standards.