ADC121S051CIMFX/NOPB

ADC121S051CIMFX/NOPB

Category: Available (Qty:9999999)
For more information, visit our official website at utsource.us

Description

BUY ADC121S051CIMFX/NOPB https://www.utsource.net/itm/p/12608076.html

Parameter Symbol Min Typ Max Unit Description
Supply Voltage VDD 2.7 - 5.5 V Operating supply voltage
Analog Input Voltage VIN 0 - VDD V Range of analog input voltage
Conversion Time tconv - 183 - μs Time to complete a conversion
Output Data Rate ODR - 5.4 - kSPS Samples per second
Resolution N - 12 - bits ADC resolution
Differential Nonlinearity DNL -1 - +1 LSB Linearity error
Integral Nonlinearity INL -2 - +2 LSB Linearity error
Power Consumption IDD - 300 - μA Current consumption in operation
Shutdown Current ISD - 0.5 - μA Current consumption in shutdown mode

Instructions for ADC121S051CIMFX/NOPB

  1. Powering the Device:

    • Ensure that the supply voltage (VDD) is within the range of 2.7V to 5.5V.
    • Connect VDD to the power supply and GND to the ground.
  2. Connecting the Analog Input:

    • Connect the analog signal to be measured to the VIN pin.
    • The input voltage should not exceed the supply voltage (VDD).
  3. Configuring the ADC:

    • Use the configuration register to set up the ADC according to your requirements, such as setting the operating mode or initiating a conversion.
    • Refer to the device datasheet for specific register settings.
  4. Starting a Conversion:

    • Initiate a conversion by writing to the appropriate register or toggling the start conversion pin.
    • Wait for the conversion time (approximately 183 μs).
  5. Reading the Result:

    • After the conversion is complete, read the result from the output data register.
    • The result will be a 12-bit digital value representing the analog input voltage.
  6. Entering Shutdown Mode:

    • To reduce power consumption, enter the shutdown mode by configuring the appropriate register bit.
    • In this mode, the current consumption drops to approximately 0.5 μA.
  7. Returning to Normal Operation:

    • To resume normal operation from shutdown mode, clear the shutdown bit in the configuration register.

For detailed information on register configurations and timing diagrams, refer to the ADC121S051CIMFX/NOPB datasheet provided by the manufacturer.

(For reference only)