Description
BUY LM2935T https://www.utsource.net/itm/p/12608202.html
Parameter |
Symbol |
Conditions |
Min |
Typ |
Max |
Unit |
Input Voltage |
VIN |
|
2.7 |
|
60 |
V |
Output Voltage |
VOUT |
|
1.23 |
|
58.8 |
V |
Dropout Voltage |
VD |
IOUT = 1A |
|
0.4 |
|
V |
Quiescent Current |
IQ |
VIN = 5V |
|
5 |
|
μA |
Load Regulation |
|
IOUT = 0mA to 1A |
|
0.01 |
|
% |
Line Regulation |
|
VIN = 3V to 60V |
|
0.01 |
|
% |
Transient Response |
|
dIOUT/dt = 5A/μs |
|
0.1 |
|
V |
Ripple Rejection |
|
f = 120Hz |
|
70 |
|
dB |
Operating Temperature |
Toper |
|
-40 |
|
125 |
°C |
Storage Temperature |
Tstg |
|
-65 |
|
150 |
°C |
Instructions for LM2935T
Power Supply Connection:
- Connect the input voltage (VIN) to the input pin.
- Ensure the input voltage is within the range of 2.7V to 60V.
Output Configuration:
- Set the desired output voltage using external resistors if adjustable version is used.
- The fixed output versions do not require external components for setting the output voltage.
Ground Connection:
- Connect the ground (GND) pin directly to the common ground of the circuit.
Capacitor Requirements:
- Use a 1μF capacitor from the output to ground for stability.
- For better transient response, a 10μF capacitor can be added at the input.
Thermal Considerations:
- Ensure adequate heat sinking if operating near maximum load conditions to maintain junction temperature within limits.
Transient Protection:
- Include transient protection devices if the input voltage source is prone to spikes or surges.
Layout Guidelines:
- Keep leads short and direct to minimize noise pickup.
- Place the regulator close to the load to reduce trace resistance and inductance.
Operating Temperature:
- Ensure the ambient temperature does not exceed 125°C for reliable operation.
Storage Temperature:
- Store the device in an environment where temperatures do not fall below -65°C or exceed 150°C.
(For reference only)