Description
BUY TLP732GP https://www.utsource.net/itm/p/12608773.html
Parameter |
Symbol |
Conditions |
Min |
Typ |
Max |
Unit |
Forward Voltage |
V_F |
IF = 20mA |
|
1.45 |
1.75 |
V |
Peak Reverse Voltage |
V_R |
|
|
|
5 |
V |
Continuous Forward Current |
I_F |
T_A = 25°C |
|
20 |
|
mA |
Pulse Forward Current |
I_F(P) |
t_P = 1ms, T_A = 25°C |
|
100 |
|
mA |
Capacitance |
C_T |
VR = 0V |
|
10 |
|
pF |
Rise Time |
t_r |
RL = 50Ω, CL = 10pF |
|
10 |
|
ns |
Fall Time |
t_f |
RL = 50Ω, CL = 10pF |
|
10 |
|
ns |
Propagation Delay Time |
t_PLH/t_PHL |
RL = 50Ω, CL = 10pF |
|
15 |
|
ns |
Storage Temperature |
T_stg |
|
-55 |
|
125 |
°C |
Operating Temperature |
T_op |
|
0 |
|
70 |
°C |
Instructions for Use:
- Mounting: Ensure the TLP732GP is mounted securely on the PCB to maintain electrical connections and thermal performance.
- Forward Current Handling: Do not exceed the continuous forward current (I_F) of 20mA at ambient temperatures. For pulse operations, ensure the pulse duration does not exceed 1ms and that the peak forward current (I_F(P)) does not exceed 100mA.
- Reverse Voltage: Keep the reverse voltage (V_R) below 5V to prevent damage.
- Temperature Considerations: Operate within the specified operating temperature range (0°C to 70°C). Store in environments where the temperature does not fall below -55°C or rise above 125°C.
- Capacitance Management: Be aware of the capacitance (C_T) when designing circuits to avoid unwanted signal delays or interference.
- Timing Parameters: Account for the propagation delay time (t_PLH/t_PHL), rise time (t_r), and fall time (t_f) in timing-sensitive applications.
- Handling Precautions: Handle with care to avoid static damage. Follow ESD handling procedures during installation.
(For reference only)