BUY OP727ARU https://www.utsource.net/itm/p/12609528.html
Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
---|---|---|---|---|---|---|
Supply Voltage | Vsupply | Continuous | 2.7 | 5.5 | V | |
Input Offset Voltage | Vos | RTI, VS = ±15V | -20 | 4 | 20 | μV |
Input Bias Current | Ib | RTI, VS = ±15V | -10 | 0.8 | 10 | nA |
Input Voltage Noise | en | f = 1kHz | 12 | nV/√Hz | ||
Slew Rate | SR | 0.3 | V/μs | |||
Bandwidth | GBW | Small Signal | 1.1 | MHz | ||
Output Voltage Swing | Vout | RL = 10kΩ, VS = ±15V | ±13.5 | V | ||
Quiescent Current | IQ | VS = ±15V | 600 | μA |
Power Supply: Ensure the supply voltage is within the specified range (2.7V to 5.5V) for optimal performance.
Input Signals: Keep input signals within the common-mode input voltage range to avoid distortion or damage.
Biasing and Decoupling: Use appropriate decoupling capacitors close to the power supply pins to reduce noise and ensure stable operation.
Output Load: Connect a load resistance of at least 10kΩ for reliable output voltage swing.
Operating Temperature: The device is designed to operate within a temperature range of -40°C to +85°C. Ensure the operating environment stays within this range.
Handling Precautions: Handle with care to prevent electrostatic discharge (ESD) damage. Use proper ESD protection measures during handling and installation.
Circuit Design: For best performance, follow recommended circuit design practices including proper layout and grounding techniques.
Storage and Packaging: Store in a dry environment and adhere to the manufacturer’s guidelines for storage and packaging to maintain component integrity.