Description
BUY IXTP120P065T https://www.utsource.net/itm/p/12610100.html
Parameter |
Symbol |
Conditions |
Min |
Typ |
Max |
Unit |
Input Voltage |
VIN |
Continuous |
4.5 |
|
65 |
V |
Output Current |
IOUT |
Continuous |
|
120 |
|
A |
Peak Output Current |
IOUT(P) |
Pulse |
|
180 |
|
A |
Junction Temperature |
Tj |
Operating Range |
-40 |
|
150 |
掳C |
Storage Temperature |
Tstg |
|
-55 |
|
150 |
掳C |
Thermal Resistance |
RthJC |
Junction to Case |
|
0.3 |
|
掳C/W |
Switching Frequency |
fSW |
Typical |
|
100 |
|
kHz |
Instructions for IXTP120P065T
Installation and Handling:
- Handle the device with care to avoid damage to the pins or body.
- Ensure proper mounting on a heatsink if operating near maximum current or temperature limits.
Power Supply Considerations:
- The input voltage must be within the specified range (4.5V to 65V).
- Use appropriate decoupling capacitors close to the power supply pins to ensure stability.
Thermal Management:
- Monitor the junction temperature to ensure it does not exceed 150掳C.
- Utilize thermal vias and adequate PCB copper area to dissipate heat effectively.
Current Limiting:
- Design the circuit to limit the output current to within the continuous rating of 120A, considering derating factors at higher temperatures.
- Account for peak currents up to 180A for short pulses.
Switching Frequency:
- Operate at a switching frequency of typically 100kHz, ensuring all components are rated for this frequency.
Environmental Conditions:
- Store the device in an environment where the temperature does not drop below -55掳C or rise above 150掳C.
- Avoid exposing the device to excessive humidity or corrosive environments.
Testing and Verification:
- After assembly, verify that the device operates within its specified parameters under all expected conditions.
- Conduct thermal imaging and electrical tests to confirm safe operation.
(For reference only)