Description
BUY SI7120ADN-T1-GE3 https://www.utsource.net/itm/p/12610237.html
Parameter |
Description |
Min |
Typ |
Max |
Unit |
Supply Voltage (VDD) |
Operating supply voltage |
1.9 |
|
3.6 |
V |
Supply Current |
Quiescent current |
|
4 |
|
μA |
Output Type |
Digital interface type |
|
I2C |
|
|
Relative Humidity Range |
Measurement range for relative humidity |
0 |
|
80 |
%RH |
Temperature Range |
Measurement range for temperature |
-10 |
|
85 |
°C |
RH Accuracy |
Accuracy of relative humidity measurement |
|
±3 |
|
%RH |
Temp Accuracy |
Accuracy of temperature measurement |
|
±0.4 |
|
°C |
Resolution |
Resolution of measurements |
|
12-bit |
|
bits |
Response Time |
Time to reach 63% of final reading |
|
8 |
|
s |
Instructions for SI7120ADN-T1-GE3
Power Supply:
- Ensure the supply voltage is within the range of 1.9V to 3.6V.
- Connect VDD and GND appropriately.
I2C Interface Setup:
- Connect SDA (data line) and SCL (clock line) to your microcontroller or processor.
- Configure the I2C bus settings as per the device requirements.
Initialization:
- Power up the sensor and initialize the I2C communication.
- Send the appropriate initialization commands to configure the sensor for operation.
Measurement Mode:
- Select the desired mode (relative humidity or temperature) by sending the corresponding command over I2C.
- Wait for the response time (typically 8 seconds) before reading the data.
Data Reading:
- Read the data from the sensor using the I2C protocol.
- Convert the raw data into relative humidity and temperature values using the provided formulas or calibration data.
Handling and Environment:
- Place the sensor in a location where it can accurately measure the environmental conditions without obstructions.
- Avoid exposing the sensor to extreme conditions outside its specified operating range.
Shutdown Mode:
- To reduce power consumption, use the shutdown mode when not taking measurements.
- Reactivate the sensor by sending the appropriate command before initiating a new measurement cycle.
For detailed specifications and advanced configurations, refer to the datasheet provided by Silicon Labs.
(For reference only)
More detail about Utsource Holding Company Limited