Description
BUY BTB04-600 TO-252 https://www.utsource.net/itm/p/12610368.html
Parameter |
Symbol |
Conditions |
Min |
Typ |
Max |
Unit |
Forward Voltage |
V_F |
I_F = 1 A |
- |
1.2 |
1.7 |
V |
Reverse Blocking Voltage |
V_R |
I_T(RMS) = 4 A |
600 |
- |
- |
V |
Maximum RMS On-State Current |
I_T(RMS) |
T_C = 70°C |
4 |
- |
- |
A |
Peak Non-Repetitive Surge Current |
I_SM |
t = 10 ms, 25°C |
- |
50 |
- |
A |
Junction Temperature |
T_J |
|
- |
- |
150 |
°C |
Storage Temperature |
T_STG |
|
-40 |
- |
125 |
°C |
Instructions for BTB04-600 TO-252
Mounting and Handling:
- Ensure that the component is mounted on a heatsink if operating at or near maximum current ratings to maintain junction temperature within safe limits.
- Handle with care to avoid damage to the leads and body.
Soldering:
- Use temperatures not exceeding 260°C for no longer than 10 seconds per operation.
- Allow sufficient cooling time between soldering operations to prevent thermal shock.
Electrical Connections:
- Verify all electrical connections are secure and correctly wired according to circuit diagrams.
- Ensure proper insulation and isolation to prevent short circuits.
Operating Environment:
- Operate within specified temperature ranges to ensure reliable performance and longevity.
- Protect from moisture and corrosive environments which can degrade performance.
Testing:
- Perform initial testing under controlled conditions to verify correct installation and functionality.
- Regularly monitor operational parameters to ensure they remain within specified limits.
(For reference only)