Description
BUY DRV5013ADQDBZR https://www.utsource.net/itm/p/12610424.html
Parameter |
Symbol |
Min |
Typical |
Max |
Unit |
Description |
Supply Voltage |
VDD |
2.7 |
|
5.5 |
V |
Operating supply voltage range |
Output Current |
IOUT |
|
100 |
|
mA |
Maximum output current |
Magnetic Sensitivity |
BOP |
|
85 |
|
G |
Operate point |
Release Point |
BRP |
|
65 |
|
G |
Release point |
Hysteresis |
HYST |
|
20 |
|
G |
Difference between operate and release points |
Response Time |
tR |
|
30 |
|
μs |
Time to switch from off to on |
Quiescent Current |
IQ |
|
1.5 |
|
mA |
Supply current in standby mode |
Operating Temperature |
TOPR |
-40 |
|
125 |
°C |
Operating temperature range |
Instructions for DRV5013ADQDBZR:
Power Supply:
- Ensure the supply voltage is within the specified range of 2.7V to 5.5V.
Magnetic Field Application:
- Apply a magnetic field greater than the operate point (BOP) to turn the device on.
- To turn the device off, reduce the magnetic field below the release point (BRP).
Handling and Installation:
- Handle with care to avoid damage to the sensitive components.
- Install in an environment that does not exceed the operating temperature range (-40°C to 125°C).
Output Load:
- Ensure the load connected to the output does not exceed the maximum output current of 100mA.
Response Consideration:
- Account for the response time of 30μs when designing circuits that require fast switching.
Current Consumption:
- Be aware of the quiescent current of 1.5mA to manage power consumption effectively.
Hysteresis Utilization:
- Use the hysteresis feature to prevent rapid switching due to noise or unstable magnetic fields.
(For reference only)