Description
BUY FDS3890_NL https://www.utsource.net/itm/p/12610698.html
Parameter |
Symbol |
Test Conditions |
Min |
Typ |
Max |
Unit |
Drain-Source On-State Resistance |
RDS(on) |
VGS = 10V, ID = 1A |
- |
25 |
- |
mΩ |
Gate Threshold Voltage |
VGS(th) |
ID = 250μA |
1.0 |
1.5 |
2.5 |
V |
Continuous Drain Current |
ID |
TC = 25°C |
- |
- |
3.8 |
A |
Power Dissipation |
PD |
TC = 25°C |
- |
- |
460 |
mW |
Junction Temperature |
TJ |
- |
- |
- |
150 |
°C |
Storage Temperature Range |
TSTG |
- |
-55 |
- |
150 |
°C |
Instructions for FDS3890_NL
Handling and Storage:
- Store the device in a dry, cool place.
- Avoid exposure to high humidity and temperatures outside the specified storage range.
Mounting:
- Ensure that the mounting surface is clean and free from contaminants.
- Use appropriate thermal management techniques if operating near the maximum junction temperature.
Electrical Connections:
- Connect the source (S), drain (D), and gate (G) terminals correctly according to your circuit design.
- Ensure that the gate voltage does not exceed the maximum rated value to prevent damage.
Operation:
- Operate within the specified temperature and current limits to ensure reliable performance.
- Monitor the device temperature, especially under continuous load conditions, to avoid exceeding the maximum junction temperature.
Testing:
- When testing the device, use the specified test conditions for accurate parameter measurements.
- Refer to the datasheet for detailed test procedures and setup instructions.
For more detailed information, refer to the full datasheet provided by the manufacturer.