Description
BUY RT6256CGQUF https://www.utsource.net/itm/p/12610740.html
Parameter |
Symbol |
Conditions |
Min |
Typ |
Max |
Unit |
Input Voltage |
VIN |
Continuous operating voltage |
4.5 |
- |
28 |
V |
Output Voltage |
VOUT |
Adjustable output |
0.8 |
- |
18 |
V |
Quiescent Current |
IQ |
VIN = 5V, VOUT = 3.3V |
- |
35 |
- |
μA |
Dropout Voltage |
VDROPOUT |
IOUT = 500mA |
- |
600 |
- |
mV |
Load Regulation |
|
1mA to 500mA |
- |
0.5 |
- |
% |
Line Regulation |
|
VIN = 5V to 28V |
- |
0.05 |
- |
% |
PSRR (Power Supply Rejection Ratio) |
PSRR |
f = 100Hz |
- |
70 |
- |
dB |
Operating Temperature |
TOPR |
Storage temperature |
-40 |
- |
85 |
°C |
Instructions for RT6256CGQUF:
Input Voltage Selection:
- Ensure the input voltage is within the range of 4.5V to 28V to avoid damage or malfunction.
Output Voltage Adjustment:
- The output voltage can be adjusted from 0.8V to 18V using external resistors. Refer to the datasheet for the specific resistor values required.
Thermal Considerations:
- Place the device in an area with adequate airflow and consider heatsinking if continuous high current operation is expected.
Capacitor Selection:
- Use low ESR ceramic capacitors for input and output filtering. Typical values are 10μF on the input and 10μF on the output.
PCB Layout:
- Keep the input and output capacitor leads short to minimize noise. Ground planes should be used to enhance thermal performance and reduce noise.
Quiescent Current:
- Be aware that the quiescent current is 35μA at typical operating conditions, which may impact battery life in portable applications.
Dropout Voltage:
- At full load (500mA), expect a dropout voltage around 600mV. Ensure the input voltage exceeds the desired output voltage by at least this amount.
Operating Temperature Range:
- The device operates reliably between -40°C and +85°C. Avoid exceeding these temperatures to prevent failure.
Load and Line Regulation:
- For optimal performance, ensure load regulation does not exceed 0.5% and line regulation stays below 0.05%.
Power Supply Rejection Ratio (PSRR):
- At 100Hz, the PSRR is typically 70dB, indicating good rejection of ripple from the input supply.
(For reference only)
More detail about Utsource Holding Company Limited