Parameter |
Symbol |
Conditions |
Min |
Typ |
Max |
Unit |
Supply Voltage |
Vcc |
Operating |
2.7 |
- |
5.5 |
V |
Standby Current |
Icc |
Vcc = 5V |
- |
10 |
- |
μA |
Active Current |
Icc |
Vcc = 5V, fosc = 8MHz |
- |
30 |
- |
mA |
Data Retention Time |
|
|
- |
10 |
- |
Years |
Write Cycle Time |
TWC |
Byte/Word/Sector |
- |
4 |
10 |
ms |
Erase Cycle Time |
TEC |
Sector |
- |
20 |
40 |
ms |
Programming Voltage |
Vpp |
Programming |
12 |
- |
13 |
V |
Operating Temperature |
Topr |
Commercial |
0 |
- |
70 |
°C |
Industrial Temp Range |
Topr |
Industrial |
-40 |
- |
85 |
°C |
Instructions for M48Z512A-70PM1
Power Supply:
- Ensure the supply voltage (Vcc) is within the specified range of 2.7V to 5.5V.
- For optimal performance and longevity, maintain a stable power supply.
Current Considerations:
- Monitor the standby current which should not exceed 10μA at 5V.
- The active current should be around 30mA when operating at 5V and 8MHz frequency.
Data Retention:
- The device retains data for up to 10 years under normal operating conditions.
Write and Erase Cycles:
- Write cycles typically take between 4ms to 10ms depending on the mode (Byte/Word/Sector).
- Erase cycles for a sector can take between 20ms to 40ms.
Programming Voltage:
- Use a programming voltage (Vpp) of 12V to 13V for reliable data programming.
Temperature Range:
- Operate the device within the temperature range suitable for your application:
- Commercial: 0°C to 70°C
- Industrial: -40°C to 85°C
Handling Precautions:
- Handle with care to avoid electrostatic discharge (ESD) damage.
- Follow manufacturer guidelines for soldering and mounting procedures.
Compatibility:
- Ensure compatibility with system requirements before integration. Review datasheets for detailed interface specifications.
(For reference only)