Description
BUY BD132 https://www.utsource.net/itm/p/12611395.html
Parameter |
Symbol |
Conditions |
Min |
Typ |
Max |
Unit |
Collector-Emitter Breakdown Voltage |
V(BR)CEO |
IC = 0, IE = 0 |
|
80 |
|
V |
Emitter-Base Breakdown Voltage |
V(BR)EBO |
IC = 0 |
|
6 |
|
V |
Collector-Base Breakdown Voltage |
V(BR)CBO |
IE = 0 |
|
80 |
|
V |
Collector-Emitter Saturation Voltage |
VCE(sat) |
IC = 1A, IB = 100mA |
1.2 |
2 |
3 |
V |
Base-Emitter Saturation Voltage |
VBE(sat) |
IC = 1A, IB = 100mA |
1.8 |
2.5 |
3 |
V |
Continuous Collector Current |
IC |
Tc = 25°C |
|
1.5 |
|
A |
Power Dissipation |
PD |
Tc = 25°C |
|
65 |
|
W |
Junction Temperature |
TJ |
Operating Range |
-55 |
|
150 |
°C |
Instructions for BD132:
Handling Precautions:
- Avoid exceeding the maximum ratings listed in the table to prevent damage.
- Ensure proper heat sinking if operating near maximum power dissipation.
Mounting:
- Use appropriate mounting hardware and thermal compound for efficient heat transfer.
- Ensure good electrical and thermal connections.
Operation:
- Operate within the specified junction temperature range to ensure reliable performance.
- For applications requiring high current, verify that the continuous collector current does not exceed 1.5A at room temperature.
Testing:
- When testing parameters like VCE(sat) and VBE(sat), use the specified test conditions (IC = 1A, IB = 100mA) for accurate measurements.
Storage:
- Store in a dry environment to avoid moisture damage.
- Handle with care to prevent physical damage or contamination of the leads.
(For reference only)
More detail about Utsource Holding Company Limited