Description
BUY TOSHIBA TLP250H(F) https://www.utsource.net/itm/p/12611433.html
Parameter |
Symbol |
Conditions |
Min |
Typ |
Max |
Unit |
Forward Voltage |
VF |
IF = 10 mA |
1.1 |
1.3 |
1.5 |
V |
Reverse Breakdown Voltage |
VBR |
IR = 1 mA |
5 |
- |
7 |
V |
Forward Current |
IF |
VR = 0 V |
- |
15 |
- |
mA |
Reverse Current |
IR |
VR = VBR |
- |
1 |
- |
mA |
Output Collector-Emitter |
VCEO(s) |
IC = 500 mA, TOPR = 25°C |
- |
30 |
- |
V |
Output Collector Current |
ICM |
VCES = 5 V, tW = 1 ms |
- |
1.5 |
- |
A |
Propagation Delay Time |
tpLH |
VINL → VIH, VOH = 1.4 V |
- |
1 |
2 |
μs |
Propagation Delay Time |
tpHL |
VINH → VIL, VOL = 0.4 V |
- |
1 |
2 |
μs |
Power Dissipation |
PD |
Ta = 25°C |
- |
625 |
- |
mW |
Operating Temperature |
TOPR |
|
-40 |
- |
105 |
°C |
Instructions for TOSHIBA TLP250H(F):
Mounting and Handling:
- Ensure proper handling to avoid damage due to electrostatic discharge (ESD).
- Use appropriate tools and follow anti-static procedures.
Power Supply Connection:
- Connect the power supply ensuring correct polarity.
- Ensure the power supply voltage is within the specified limits to prevent damage.
Input Signal:
- Apply input signals within the rated forward current (IF) and ensure reverse voltage does not exceed the breakdown voltage (VBR).
Output Load:
- Connect the load to the output terminals ensuring the collector-emitter voltage (VCEO) and collector current (ICM) are within the specified limits.
Heat Management:
- Consider heat dissipation requirements, especially when operating near maximum power dissipation (PD). Use heatsinks if necessary.
Operating Temperature:
- Operate the device within the specified temperature range (-40°C to +105°C) to ensure reliable performance.
Propagation Delay:
- Account for propagation delay times in system timing design to ensure accurate operation.
Storage:
- Store in a dry, cool place away from direct sunlight and sources of heat.
(For reference only)