Description
BUY TJA1020T/CM118 https://www.utsource.net/itm/p/12611686.html
Parameter |
Symbol |
Conditions |
Min |
Typ |
Max |
Unit |
Supply Voltage |
Vcc |
Operating range |
3.0 |
- |
5.5 |
V |
Standby Current |
Isb |
Vcc = 5V, EN = L |
- |
1 |
- |
μA |
Active Current |
Icc |
Vcc = 5V, TxD = 20 kbps |
- |
9 |
- |
mA |
Receiver Input Voltage |
V(Iin) |
VIH = 0.7 × Vcc |
2.1 |
- |
3.85 |
V |
Output Low Voltage |
VOL |
IOH = 4mA |
0.1 |
- |
0.4 |
V |
Output High Voltage |
VOH |
IOL = -4mA |
4.2 |
- |
Vcc-0.4 |
V |
Differential Input Level |
Vdiff |
Receiver threshold |
200 |
- |
- |
mV |
Data Rate |
Bit/s |
Maximum |
- |
- |
1 |
Mbps |
Operating Temperature |
Toper |
- |
-40 |
- |
125 |
°C |
Instructions for TJA1020T/CM118
Power Supply Connection:
- Connect the Vcc pin to a stable power supply within the operating range of 3.0V to 5.5V.
- Ensure the GND pin is connected to the system ground.
Enable Pin (EN):
- The EN pin controls the active or standby state of the device.
- Set EN high (Vcc) to enable the transceiver.
- Set EN low (GND) to put the device into low-power standby mode.
Data Transmission:
- Use the TXD and RXD pins for data transmission and reception.
- Ensure the baud rate does not exceed 1 Mbps for reliable communication.
Termination Resistors:
- For optimal performance, connect a 120Ω termination resistor between CAN_H and CAN_L at both ends of the bus.
Temperature Considerations:
- Operate the device within the temperature range of -40°C to 125°C to ensure reliability and longevity.
Electrostatic Discharge (ESD) Protection:
- Handle the device with appropriate ESD precautions to prevent damage.
Mounting and Layout:
- Follow recommended PCB layout guidelines to minimize noise and interference.
Signal Integrity:
- Keep signal traces as short as possible to maintain signal integrity, especially for high-speed applications.
(For reference only)