Description
BUY HCPL-817-300E https://www.utsource.net/itm/p/12611979.html
Parameter |
Symbol |
Conditions |
Min |
Typ |
Max |
Unit |
Forward Voltage |
VF |
IF = 20mA |
|
1.2 |
1.5 |
V |
Reverse Voltage |
VR |
|
|
|
5 |
V |
Forward Current |
IF |
Continuous |
|
|
50 |
mA |
Peak Pulse Current |
IFP |
t < 1ms |
|
|
150 |
mA |
Reverse Current |
IR |
VR = 5V |
|
|
100 |
μA |
CTR (Current Transfer Ratio) |
CTR |
IF = 5mA, VO = 5V |
100 |
300 |
600 |
% |
Output Collector-Emitter Voltage |
VCEO |
IC = 10mA |
|
|
70 |
V |
Output Collector Current |
ICM |
|
|
|
50 |
mA |
Rise Time |
tr |
IF = 5mA, RL = 100Ω |
|
|
2 |
μs |
Fall Time |
tf |
IF = 5mA, RL = 100Ω |
|
|
2 |
μs |
Instructions for HCPL-817-300E:
Power Supply and Connections:
- Ensure the forward voltage (VF) does not exceed 1.5V when operating at 20mA to prevent damage.
- Keep reverse voltage (VR) below 5V to avoid breakdown.
Current Handling:
- The device can handle a continuous forward current (IF) up to 50mA. For pulse applications, ensure peak pulse current (IFP) does not exceed 150mA for durations less than 1ms.
- Limit reverse current (IR) to no more than 100μA at 5V reverse voltage.
CTR Consideration:
- The current transfer ratio (CTR) ranges from 100% to 600% under typical conditions (IF = 5mA, VO = 5V). Design circuits considering this range for reliable operation.
Output Specifications:
- Do not exceed 70V for collector-emitter voltage (VCEO) and limit output collector current (ICM) to 50mA.
Timing Parameters:
- Account for rise time (tr) and fall time (tf) of up to 2μs in timing-sensitive applications.
Mounting and Environment:
- Ensure proper mounting to maintain thermal stability. Avoid exposing the device to excessive heat or moisture.
Safety Precautions:
- Always follow safety guidelines during handling and installation to prevent electrical shock or damage to the device.
(For reference only)