Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
---|---|---|---|---|---|---|
Supply Voltage | VDD | Operating | 2.7 | 5.5 | V | |
Output Current | IOUT | Per Channel | 40 | mA | ||
Power Dissipation | PD | All Channels On | 1000 | mW | ||
Operating Temperature | Toper | -40 | 85 | °C | ||
Storage Temperature | Tstg | -65 | 150 | °C | ||
Input Voltage Range | VIN | Differential Mode | -0.3 | 5.8 | V |
Power Supply: Ensure the supply voltage (VDD) is within the range of 2.7V to 5.5V. This device is designed to operate efficiently within this voltage range.
Output Handling: Each channel can source up to 40mA of current. Be cautious not to exceed this limit to avoid damaging the component.
Thermal Management: The device can dissipate up to 1000mW when all channels are on. Proper heat sinking or cooling solutions should be considered if operating near this power level.
Temperature Considerations: Operate the device within the temperature range of -40°C to +85°C. Storage should be between -65°C and +150°C.
Input Signal: The differential input voltage range should not exceed -0.3V to +5.8V relative to ground to prevent damage or erratic behavior.
Installation and Handling: Use appropriate anti-static precautions when handling the MAX3083EESD to prevent damage from electrostatic discharge (ESD).
Schematic Review: Always review the schematic layout carefully to ensure correct connections, especially for power and ground lines, which are critical for reliable operation.