LPF-120W

Kategori: Others Power Supply Tersedia
Untuk maklumat lanjut, lawati laman web rasmi kami di winstonelectric.com.my

Penerangan

Features:
·Universal AC input range/Full range
·Built-in active PFC function
·Protections: Short circuit / Over load/Over voltage/Over temperature
·Cooling by free air convection
·Class II power unit
·IP67 design for indoor or outdoor installations
·Suitable for LED lighting and moving sign applications
·Compliance to worldwide safety regulations for lighting
·Suitable for dry / damp / wet locations
·3 years warranty


Model LPF-120-5000 LPF-120-3400 LPF-120-2500 LPF-120-2100
 
 
Output
DC voltage 24V 36V 48V 54
Constant current region 16~24V 24~36V 32~48V 32~54V
Rated current 5000mA 3400mA 2500mA 2100mA
Rated  power 120W 122.4W 120W 113.4W
Ripple&noise (max.) 3.6Vp-p 4.5Vp-p 4.6Vp-p       4.8Vp-p
Voltage tolerance ±5.0%  
Current  tolerance ±5.0%  
Line  regulation ±3.0%  
Load  regulation ±5.0%  
Setup time 1200ms/115VAC,500ms/230VAC(Full load)  
      Input Voltage range 90~264VAC 47~63Hz,127~370VDC  
AC current (Typ.) 0.8A/115VAC    0.4A/230VAC  
Efficiency 89% 90% 91% 91%
Power factor PF>0.9/230VAC ,PF>0.92/115VAC(at full load)  
Inrush current Cold start current 40A/230VAC  
Leakage current <0.75mA/240VAC  
 
Protection
Overload 95~110%  rated output power  
Protection type : Constant current limiting, recovers automatically after fault condition is removed  
Over voltage 30~ 33V 44~ 47V 52~ 62V  63~68V
Protection type : Shut down o/p voltage, re-power on to recover  
Short circuit Hiccup mode, recovers automatically after fault condition is removed  
Over temperature 90℃±10℃(RTH2)
Protection type : Shut down o/p voltage, re-power on to recover
 
Environment Working temp, humidity -30℃~+50℃,20%~90%RH  non-condensing  
Storage temp,humidity -40℃~+80℃,10%~95%RH non-condensing  
Temp. coefficient ±0.03%/℃ (0 ~ 50℃)  
Vibration   10~500HZ,2G 10min/1cycle,period for 60min, X.Y.Z each axes  
 
Safety&EMC
Safety standard         UL8750, TUV EN61347-1,EN61347-2-13,UL60950-1,IP67  Certificated  
Withstand voltage I/P-O/P:3KVAC ,I/P-FG:1.5KVAC,O/P-FG:0.5KVAC   
Isolation resistance I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH  
EMC interference Compliance to EN55015,EN61000-3-2 Class C(≥65% Load)  
EMC emission Compliance to EN61000-3-2  Class C(≥75% Load); EN61000-3-3  
EMC immunity Compliance to EN61000-4-2 ,3,4,5,6,8,11; ENV50204,EN55024,EN61547,light industry level (surge 4KV),  criteria B  
Others MTBF 420K hrs min. MIL-HDBK-217F (25℃)  
Dimension 204*49*34mm(L*W*H)  
Packing 0.62kg/30pcs/19.5kg/0.027 m³/0.95CUFT  
 
NOTE:
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 ℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 60% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design.
5.Derating may be needed under low input voltage. Please check the static characteristics for more details.
6.Setup time is measured at cold start condition. Turning ON/OFF the power supply frequently may  increase  the set up time.
7.The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will
be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.

Lebih maklumat tentang Winston Resources
Winston Resources
Winston Resources Lab & Industrial Process Equipment Selangor, Electronic Components Supply Kuala Lumpur (KL), Processing Machine Supplier Malaysia ~ Winston Resources