Engineering Services

Engineering Services

Kategori: Engineering Services Tersedia
Untuk maklumat lanjut, lawati laman web rasmi kami di saturnpyro.com

Penerangan

Saturn Pyro offers in house consultancy & engineering services in addition to products & solutions it offers. The services are supported with unmatched availability of advanced portable instrumentation and software tools.

Our services are concluded and complemented with solutions; effectively concluding an application.

The services include:

Electrical Safety Survey

i. Infra red thermal imaging : A non-intrusive predictive maintenance tool to identify potential fire and shock hazards through infra red scanning of electrical installations : switchgear, cable terminals, bus bars, transformers, Motors, etc. Thermal signatures derived through thermal scan help in pin pointing cause of overheating and initiate preventive action in advance of hazardous conditions to materialize.

Thermal Imaging

Customer benefits : minimize breakdowns and repair & replacement costs, enhance uptime for production, minimize conditions that may lead to accidents and risk to human life.

ii. Earth resistance test : Advanced instrumentation for periodic testing of earth resistance. It offers unique advantage over conventional fall of potential ( 3 point ) method that requires insertion of ground pins and disconnection of earth station. The advanced digital earth resistance tester is multi-function and enables stackless earth resistance measurement without earth station disconnection or use of earth probes. It can also be used to measure soil resistivity ( specific earth resistance – Wenner & Schlumberger Array )

Customer benefit : Earth resistance test could be conducted while the installation is live and operational.

iii. Load survey : Portable power, energy and power quality analyzers enable recording of electrical parameters ay key location to establish load profile.
Customer benefit : Establishment of power & energy trends for various purposes such as identifying peak and base load, inrush current recording of motors, harmonics, voltages across N-G, earth leakage currents, etc. All measurements are carried out while equipment are operational ( no requirement of shutdown )

Power System Studies – Short Circuit, Load Flow & Protection Discrimination on ETAP

Power system studies covering the three basic requirement are conducted on ETAP software.

A short-circuit study is an analysis of an electrical distribution network that determines the magnitude of the currents that may flow during an electrical fault.

Comparing these calculated values against the equipment ratings is the first step to ensuring that the power system is safely protected.

Once the expected short-circuit currents are known, a protection coordination study is performed to determine the optimum characteristics, ratings and settings of the power system protective devices.



Short Circuit Study includes

Protection Discrimination Studies

 

Load Flow Studies

Load flow studies primarily offer the voltage profile of the distribution network.

A load flow study calculates the voltage drop on each feeder, the voltage at each bus, and the power flow and losses in all branch and feeder circuits. Load flow studies determine if system voltages remain within specified limits under normal or emergency operating conditions, and whether equipment such as transformers, switchgear and conductors are overloaded.

Load flow studies help to

 

Load flow studies comprise of

Arc Flash Assessment & Labeling

What is an arc flash
Arc flash is a condition of serious electrical hazard and is a result of an electrical fault. Other conditions that may include accidental contact with live electrical equipment, breakdown of insulation, etc. Moreover an equipment that is not adequately protected or does not have the withstand capacity for the fault current is likely to pose arc flash hazard.

What happens during an arc flash
An arc flash is a sudden release of high energy which is proportional to available short circuit current at the location of fault. An arc flash is characterized with high explosion with temperatures of area surrounding arc flash reaching thousands of deg C in a fraction of a second. Such temperatures could set cloths on fire even from a significant distance, can cause severe burns, the bright light of flash & sound of explosion could bring temporary blindness and deafness. Molten metal of switchboards, copper from bus bars, nut bolts become shrapnel that fly in all directions at high velocity.

Electric Arc Flash

How to mitigate risk of an arc flash
Risk from an arc flash potential may not be entirely mitigated, however a better defense against it could be built. Arc flash protection is a step-by-step process.
First step towards safety from an arc is to carry out arc flash assessment.

An arc flash assessment includes identification of locations where arc flash hazard may exist and at what intensity.

An awareness session would follow an arc flash assessment report. It will discuss safety practices around electrical installation and use of PPE ( personal protection equipment ), defining various terms such as flash protection boundary, limited approach, restricted approach & prohibited approach.

The short circuit studies and an adequate & co-ordinated protective relaying offers realistic values of arc flash severity. Arc flash hazard at any given location is expressed as incident energy and is measured in cal / cm sq

Arc flash labels are fixed at all hazardous areas with essential data that warn and instruct personnel.



Saturn Pyro offers you

 


 

 




Design of Earthing & Lightning Protection, Touch & Step Potential Testing

Earthing & Lightning Protection

Earthing design considerations have become more complex due to increased use of power electronics, automation & IT- equipment that require not only low impedance path for protective earth but also dissipation of earth leakage currents at the fundamental frequency as well a high frequency. It also means shaping of electrical field in ground around an earth electrode to enable control of hazardous voltage gradients.

Lightning protection
Lightning protection design considerations apply to facilities with tall structures and also to sub stations, power generation plants, factories, etc. Lightning strikes involve high energy at voltages of 500 KV and currents 50 KA; although lasting for a very short duration of 10 to 50 micro seconds.

Designing Earthing & Lightning Protection

Lightning can cause deaths and injuries to human beings and severe damage to buildings and structures. The threat of damage to property and equipment is growing if IT systems, communication networks and sensitive electronic devices are being used without proper protection. When lightning strikes a structure, the very high current searches for the easiest path like metal pipes, power and communication wiring, metal railings — all of which are not designed to carry high currents. This generates heating, melting, fire and smoke.

Saturn Pyro advocates a systematic approach to earthing & lightning protection design which covers

The services are also available to

Power Quality Management
Power quality refers to quality of key electrical parameters that affect the smooth and safe operation of an equipment : voltage, frequency, voltage waveform, harmonics, etc.

Electrical power received from electric utility can have issues such as sags & swells, sustained over and under voltages, interruption, transient over voltages, voltage harmonic distortion. These are due to collective effect of poor line regulation, lack of voltage regulators such as tap changers, sudden switch in or switch out of large loads, over head line faults such as falling of a branch, tracking by a bird and arcing load such as a steel plant.

Power quality may also be affected by equipment within a plant, such as power rectifiers & inverters, variable frequency drives, UPS, lighting, etc. Ironically the very equipment that are sensitive to power quality may contribute to power quality issues

Power quality issues are responsible for damage to or malfunction of critical equipment, loss of production, loss of revenue and high cost of repair / replacement.

Saturn Pyro offers complete solution to power quality issues
Comprehensive power quality survey with advanced instrumentation. This includes long term power quality disturbance monitoring covering voltage quality, transient waveform capture, harmonic assessment, high frequency impulse capture.

Formulation of solution – includes voltage regulators, active & hybrid harmonic filters, de-tuning of PFCs

Energy Audit
Energy Audit is the first step to conservation of energy which is a larger objective.
Energy audit analyses various energy consuming process and identifies opportunities that will help reduce energy consumption.
Saturn Pyro offers energy audit services that cover Electrical, Aircon : Dx and chilled water system, pumps, cooling towers, ventilation, compressed air, etc
Energy audit report offers solutions to reduce energy consumption.

Data Center Assessment Services
SaturnPyro Offers services in Data Center assessment with an objective to optimize the overall performance and improve reliability of the energy infra.

The services would be beneficial to Enterprise Data Center, co-Location sites and Disaster back up sites alike.

Data Center Design and Performance Assessment Audit
Design & operations review : to identify conditions what may affect reliability, redundancy, uptime for critical power and cooling

CFD Modelling : to establish cooling performance and help improve thermal management of the racks. CFD modelling offers insights into the cooling performance, helps simulate various operational and risk conditions to establish the reliability and efficiency of cooling, scope for expansion and additions

Data Center CFD

Detailed Power & Cooling assessment to establish DCIE & PUE : chiller performance assessment, CRAC performance assessment, assessment of UPS and raw powered equipment, establish baseline consumption, establish IPLV of cooling infra, etc


Saturn Pyro provides reliable engineering services such Electrical Safety Survey, Power System Studies (Short Circuit, Load Flow & Protection Discrimination on ETAP), Arc Flash Assessment & Labeling, Design Of Earthing & Lightning Protection, Measurement Of Touch & Step potentials, Power Quality Management, Energy Audit and Data Center Performance Assessment. We also provides Electrical Safety Survey such as Inspection of an electrical installation, Identification of risk (electrical hazards), Review of documentation, operations & maintenance procedures, contingency planning, Generation of report in details of risk potentials and plan for mitigation, Closing report post implementationas. Available in Pulau Pinang, Johor, Kuala Lumpur (KL), Selangor and anywhere in Malaysia / Singapore / Bangalore / India / Mumbai.

Lebih maklumat tentang Saturn Pyro Sdn Bhd
Saturn Pyro Sdn Bhd
Saturn Pyro Sdn Bhd Energy Meters Supplier Johor Bahru (JB), Energy Management Malaysia, Selangor, Power Quality Analyzers Supply Kuala Lumpur (KL), Penang ~ Saturn Pyro Sdn Bhd