Level and flow measurement in the hydraulic oil station

Level and flow measurement in the hydraulic oil station

Kategori: Paper industry Tersedia
Untuk maklumat lanjut, lawati laman web rasmi kami di vginstruments.com.my

Penerangan

Hydraulic oil station

Level and flow measurement in the hydraulic oil station

Level and flow measurement in the hydraulic oil station
Hydrostatic, Flow
Level and flow measurement in the hydraulic oil station
Radar, flow

Process data

Measuring task
Level and flow measurement
Measuring point
Tank
Measuring range up to
2 m
Medium
Machine oil
Process temperature
+20 … +80 °C
Process pressure
+5 … +6 bar
Special challenges
High pressures

Application

In the press section of a paper machine, very high pressures are needed for dewatering the stock. Hydraulic oil stations provide the supply to the various parts of the machine as well as filtering and cooling the recirculating lubrication system. Integrated pumps provide oil to the required locations and to enable fully automatic operation of the station, the flow rate and the level in the supply tanks must be measured.

Your benefit

Reliable
Reliable measurements ensure consistent operation of the paper machine
Cost effective
Differential pressure transmitters with pitot tube for low-cost oil flow measurement
User friendly
Convenient reading of the level directly at the measuring point
 

Lebih maklumat tentang VG Instruments (SEA) Sdn Bhd
VG Instruments (SEA) Sdn Bhd
VG Instruments (SEA) Sdn Bhd VEGA Instruments, Level Gauge Malaysia, Pressure Measurement, Transmitter Supplier ~ VG Instruments (SEA) Sdn Bhd