Probe types |
F |
N |
|
---|---|---|---|
Working principle |
Magnetic induction |
Eddy current |
|
Measuring range |
0-1250 μm |
0-1250 μm, |
|
Minimum resolution |
0.1μm |
||
Tolerance |
Zero point calibration |
±(3%H+1) μm |
±(3%H+1.5) μm |
Two points calibration |
±{(1-3)%H+1}μm |
±{(1-3)%H+1.5}μm |
|
Measuring |
Min. curvature radius |
Convexity 1.5 mm |
Convexity 3 mm |
Min. area diameter |
Φ7 mm |
Φ5 mm |
|
Critical thickness |
0.5 mm |
0.3 mm |
|
Operating environment |
Temperature: 0°C – 40°C |
||
Humidity: 20%-90% |
|||
No strong magnetic field |
|||
Power |
2 pcs AAA 1.5 V battery |
||
Dimension |
110 x 50 x 23 (mm) |
||
Weight |
100 g |