i-Vu® WSHP Water-to-Water Open Controller OPN-WSHPW2WM

i-Vu® WSHP Water-to-Water Open Controller OPN-WSHPW2WM

Kategori: Carrier Tersedia
Untuk maklumat lanjut, lawati laman web rasmi kami di unitedfaith.com.my

Penerangan

Product Integrated Controller

Carrier’s Water-to-Water (W2W) Open controller is an integrated component of a Carrier water-to-water source heat pump. The W2W Open controller continuously monitors and regulates heat pump operation with reliability and precision. This advanced controller features a sophisticated, factory-engineered control program that provides optimum performance and energy efficiency. For added flexibility, the W2W Open controller is capable of stand-alone operation. It can also be integrated with any Building Automation System using the BACnet®, Modbus®, LonWorks®*, or N2 protocol.

*Requires LON Option Card (p/n LON-OC)


carrier-bacnet-international-member
carrier-bacnet-testing-laboratories

Application Features

Hardware Features

System Benefits

BACnet Support Advanced Application Controller (B-AAC), as defined in BACnet 135-2001 Annex L
Communication Ports Network Comm port: EIA-485 port for BACnet MS/TP, Modbus RTU, or N2 communications
(protocol and baud rate are DIP switch selectable);
Comm Option port: For connecting a LON Option Card (p/n LON-OC);
Local Access port: For system start-up and troubleshooting (115.2 kbps);
Rnet port: For connecting a T1 temperature sensor.
Inputs 5 analog inputs: Leaving Load Water Temperature, Entering Load Water Temperature (optional), Leaving Source Water Temperature, Outdoor Air Temperature (optional) and Relative Humidity (optional). All AI’s have 10 bit A/D resolution.
5 binary inputs: Compressor 1 Status, Compressor 2 Status, Compressor 3 Status, Remote Occupancy Contact, and Safety Shutdown.
Outputs 8 binary outputs:Stage 1 through Stage 4 Capacity Control, Reversing Valve, Source Water Pump/ Isolation Valve, Load Water Pump, and Alarm Lamp. Relay contacts rated at 3A max @ 24VAC, configured normally open
Real Time Clock Battery-backed real time clock keeps track of time in event of power failure
Battery 10-year Lithium CR2032 battery provides a minimum of 10,000 hours of trend data & time retention during power outages
Protection Incoming power and network connections are protected by non-replaceable internal solid-state polyswitches that reset themselves when the condition that causes a fault returns to normal. The power, network, input, and output connections are also protected against voltage transient and surge events.
Status Indicators LED status indicators for network communications, run status, error, power, and all digital outputs
Controller Addressing Rotary dip switches set BACnet MS/TP, Modbus, or N2 address of controller
Listed by UL-873, FCC Part 15-Subpart B-Class A, CE EN50082-1997
Environmental Operating Range Operating: -40 to 158ºF (-40 to 70ºC)
10 to 95% RH, non-condensing
Storage: -40 to 158ºF (-40 to 70ºC)
10 to 95% RH, non-condensing
Power Requirements 24VAC +/- 10%, 50-60Hz, 14 VA power consumption, 26VDC (25V min, 30V max), single class 2 source only, 100 VA or less

Lebih maklumat tentang United Faith Sdn Bhd
United Faith Sdn Bhd
United Faith Sdn Bhd Air Conditioner Parts Supplier Selangor, Air Cond Services Kuala Lumpur (KL), Refrigeration Tools Malaysia, Singapore ~ United Faith Sdn Bhd